Unit type: CJ1 Basic I/O Units.
Product name: Interrupt Input Unit.
Specifications: I/O points, 16 inputs;
Input voltage current, 24 VDC, 7mA;
Commons: 16 points, 1 common;
Input pulse widt conditions, ON time:
0.05 ms max. OFF time: 0.5 ms max;
Max. Units mountable per Unit, 2;
External connection, Removable terminal block CRT1-OD08SL-1 PDF catalog .
No. of words allocated: 1 word
CRT1-OD08SL-1
Current consumption: 5V, 0.08A; 24V, --.
Standards: UC1, N, L, CE.
High-speed Starting of I/O InterruptTasks.
Use Up to Two Units for a Total of Up,
to 32 Interrupt Inputs.
Receive inputs to start I/O interrupt tasks.
When the Interrupt Input Unit receives an input,
the CPU Unit will interrupt execution of the,
cyclic tasks in the normal CRT1-OD08SL-1 PDF catalog .
program and execute an I/O interrupt task. UM: 31.2K words.
DM: 6K words.
EM: 6Kx3 banks(18K) words.
Instruction processing time (basic instructions): 0.1 µ.s min.
No. of I/O points: 1, 184 points.
Max. no.of con-necting Expansion I/O Racks: 3 Racks.
Max. no. of connecting High-density I/O Units(i.e., Group-2): Unavailable.
Max. no. of con-necting Special I/O Units: 10 CRT1-OD08SL-1 PDF catalog .
RS-232C: NO.8 pts, 1.2 A, 120 VACProduct name: N@@-type CPU Units with 60 I/O Points.
Specifications: Power Supply, 24 VDC; Inputs, 36; Outputs, 24;
Output type: Transistor (sinking).
Program capacity: 8K steps.
memory Data capacity: 8K words OMRON CRT1-OD08SL-1 PDF datasheet.
External powersupply(24 VDC): --.
Current consumption: 5 V, 0.31A; 24 V,0.02A.
Standards: UC1, N, L, CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient OMRON CRT1-OD08SL-1 PDF datasheet.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection OMRON CRT1-OD08SL-1 PDF datasheet. 24 VDC.NO. OF I/O SLOTS: 11 SLOTSConnects CQM1H to G730 SYSMAC BUS remote I/O
modules; max. 64 I/O (32 or 16 inputs or outputs, DIP switch selectable)
Number of I/O points per Master: 128
Communications cycle time: 187.5 kbps
Max. transmission distance: 200 m
One master and two expansions allowed per systemUnit type: CJ1 Basic I/O Units.
Product name: DC Input Units.
Specifications: I/O points, 64 inputs;
Input voltage and current: 24 VDC, 4.1 mA;
Commons, 16 points, 1 common; External connection,
MIL connector; No. of words allocated, 4 word.
Current consumption: 5V,, 0 CRT1-OD08SL-1 datasheet. 09A; 24V, --.
Standards: UC1, N, L, CE.
A Wide Range of Basic Input,
Units for High Speed Input and,
Different Applications.
Receive ON/OFF signals from external,
devices into the PLC System to update,
I/O memoory in the CPU Unit CRT1-OD08SL-1 PDF catalog .
New high-speed input models CJ1W-ID212 and,
CJ1W-ID233 are now available. These units can,
help to increase system throughput.