LK Automation Limited
Home >> Download >> OMRON >> Catalog Download >> D4N-9220 PDF catalog OMRON D4N-9220 datasheet PDF datasheet

D4N-9220 PDF catalog OMRON D4N-9220 datasheet PDF datasheet

Product model: D4N-9220
Name: Safety Limit Switch
Brand: OMRON
Sort: PDF datasheet
File language: English
File size: 5.69MB
Receptacle box: G 1/2 Conduit.
Indicator: Without indicator.
Actuator: Top plunger, Roller.
Approved standards: UL, CSA.
The Limit Switch with Better Seal,
Shock Resistance, and Strength.
A double seal on the head, a complete gasket cover, and,
other features ensure a better seal (meets UL NEMA 3, 4, 4X, 6P, 12, 13) OMRON D4N-9220 PDF datasheet.
Wide standard operating temperature range:
-40°C to +100°C (standard type) D4N-9220
Models with fluoro-rubber available for greater resistance to chemicals.
Block mounting method also reduces downtime for maintenance.
DPDT, double-break models available for complex operations.
Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved model OMRON D4N-9220 PDF datasheet. ) Actuator: One-way roller arm lever (horizontal).
Conduit size: 1-conduit; Pg13.5.
Built-in switch mechanism: 1NC/1NO (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement OMRON D4N-9220 PDF datasheet.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Type: Pull-on lock.
Contact gap: 1 mm.
Mounting: Panel mounting.
Contact form: SPST-NO+SPST-NC.
Door Interlock Power.
Switch with Minimum.
Contact gap of 3 mm.
Offers the minimum contact gap of 3 mm required.
for power switches as standard equipment.
Safety considerations include a double return spring,
and direct drive positive contact opening feature.
Pull-on lock model for easy maintenance is also available. Actuator: Roller lever (stainless steel roller).
Conduit openings: G1/2 (PF1/2).
2NC (Slow-action).
Robust safety limit switch with metal housing.
Slow-action and snap-action contact with,
certified direct opening operation certification.
Direct opening mechanism (NC contacts only) added to,
enable opening contacts when faults occur, such as fused contacts.
Safety of lever settings ensured using a mechanism that,
engages a gear between the operating position indicator plate and the lever.
Equipped with a mechanism that indicates the applicable,
operating zone, as well as push-button switching to control left and right motion D4N-9220 PDF catalog.
Head seal structure strengthened to improve seal properties.
(TÜV: IEC IP67, UL: NNEMA 3, 4, 4X, 6P, and 13) D4N-9220 PDF catalog.
Wide standard operating temperature range: –40 to 80°C (standard type).
Certified standards: UL, CSA, EN (TÜV), and CCC.
Related products
OMRON
Pull-reset Safety Limit Switch
D4N-1D2GR
OMRON Pull-reset Safety Limit Switch D4N-1D2GR
Actuator: Adjustale roller lever, form lock
OMRON
Safety Limit Switch
D4N-8E72
OMRON Safety Limit Switch D4N-8E72
Actuator: One-way roller arm lever vertical
OMRON
Safety Limit Switch
D4N-4F2H
OMRON Safety Limit Switch D4N-4F2H
Actuator: Adjustale roller lever, form lock
OMRON
Safety Limit Switch
D4N-4226
OMRON Safety Limit Switch D4N-4226
Actuator: Roller lever resin lever, earing