Appearance: L-shaped.
Sensing method: Through-beam type (with slot).
Cable length: 2 m.
Sensing distance: 5 mm (slot width).
configuration Output: Dark-ON.
Indicator mode: No incident light.
Model: NPN output.
Slim, Compact Photomicrosensor.
that is still easy to use.
Compact, thin profile enables dense mounting OMRON E2A-M18KS08-M1-C1 PDF catalog.
Indicator is visible from both sides.
Wide operating voltage range: 5 to 24 VDC
E2A-M18KS08-M1-C1 Sensing method: Through-beam type (with slot).
Sensing distance (slot width): 13 mm (slot width).
Output type: NPN output.
Outpu configuration: Dark-ON.
A Wide Slot Width of 13 mm and.
Superior Resistance to Light.
Interference and Noise.
Noise resistance equivalent to photomicrosensors with built-in amplifiers OMRON E2A-M18KS08-M1-C1 PDF catalog.
Resistance to common noise at least 30 times that of previous models.
Resistance to inverter noise at least 10 times that of previous models.
Reverse polarity protection built in. Terminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 3.2 dia.
Protective tubing length L: 15 cm.
Lead wire type: Standard.
Lead wire length M: 1m.
A Wide Variety of High-precision OMRON E2A-M18KS08-M1-C1 PDF catalog.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. High performance price ratio standard type proximity sensor.
Standard cable protector.
The new DC two-wire type.
Non polar proximity sensor.
Type: DC three wire / connector type.
Shape: non shield, M8.
Detection range: 2mm.
Output configuration: PNP.
Action mode: NO. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: RS-485.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/SSTOP, alarm), interactive display PV/SV E2A-M18KS08-M1-C1 PDF datasheet.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E2A-M18KS08-M1-C1 PDF datasheet.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.