Appearance: Standard.
Sensing method: Throughbeam type(with slot).
Connecting method: Connector(4 poles).
Sensing distance: 5 mm (slot width).
Output configuration: Dark-ON/Light-ON (selectable).
Indicator mode: No incident light.
Model: NPN output.
Global Standard Slot-type.
photomicrosensors with 50- to,
100-mA direct switching capacity OMRON E2B-M18KN10-M1-B2 PDF catalog.
Series includes models that enable switching between,
dark-ON and light-ON operation
E2B-M18KN10-M1-B2
Response frequency as high as 1 kHz.
Easy operation monitoring with bright light indicator.
Wide operating voltage range: 5 to 24 VDC.
Models in which the light indicator turns ON for dark-ON,
operation are also available.
A wide range of variations in eight different shapes OMRON E2B-M18KN10-M1-B2 PDF catalog.
Flexible robot cable is provided as a standard feature. The main body: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use OMRON E2B-M18KN10-M1-B2 PDF catalog.
Event input points: -.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay. High performance price ratio standard type proximity sensor.
Standard cable protector.
The new DC two-wire type.
Non polar proximity sensor.
Type: DC / wire type.
Polarity: there.
Shape: shield, M8.
Detection range: 2mm.
Action mode: NO. Size: 48 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 4.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes the proocess of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output E2B-M18KN10-M1-B2 PDF datasheet.
Through the infrared port can be carried out from the frront of the communication E2B-M18KN10-M1-B2 PDF datasheet.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.