Product model: FX2NC-100BPCB
Name: Connecting cable
Brand: MITSUBISHI
Sort: PDF datasheet
File language: English
File size: 50.49MB
Extended power supply for CPU module with built-in power supply.
Bus conversion module is required when using. Maximum can be connected to 2 sets. 5 in each package.
Application: to protect the surface of the display, to prevent the operation of oil or other material pollution.
The contaminated part of the adhesive film can be replaced MITSUBISHI FX2NC-100BPCB PDF catalog.
Specifications: 120*92mm FX2NC-100BPCB
Application Series: F940GOT, hand held GOT. Can be isolated to obtain DC24/48/100V, AC100/200V input signal.Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Input / output type: DC input (drain / source).
Input points: 8 points.
Input and output points: 8 points.
Because all models of FX series are built in high speed counter,
So the high speed control can be realized by the simple procedure MITSUBISHI FX2NC-100BPCB PDF catalog.
The input of the basic unit is built in the anti jitter filter,
One part as digital filter,
Sensitivity adjustment unit can reach 1ms.
Using high speed counter automatically adjusted to the minimum value.
Through the high cost of the built-in positioning function and the expansion function to increase the number of control axis MITSUBISHI FX2NC-100BPCB PDF catalog.
Extended function expansion board and special adapter,
Data links and communication with external serial devices.
FX2N extension module.
The expansion module is an input and output expansion device of the power supply from the basic unit or the expansion unit,
Can choose the relay or crystal output models, to 8 points for the unit to connect.
Can be extended to FX3GA/FX3G, FX3GE, FX3GC, as well as FX3U, FX3UC series,
When connecting to FX3UC or FX3GC, you need FX2NC-CNV-IF or FX3UC-1PS-5V.
The number of connection points depends on the basic unit and the expansion unit. Display and setting data in a programmable controller.
Can monitor or set the timer, counter, data registers (FX1S and FX1N of the host computer). 20 pin connector on both ends of the circular multi-core cable.
Length 1.5M. "MITSUBISHI inverter FR-F740P series.
Voltage level: three phase 400V.
Frequency converter capacity: 185KW.
It is based on the overall effect of three-phase waveform generation,
In order to approach the ideal circular rotating magnetic field in the air gap of the motor,
A generation phase modulation waveform control inscribesthe polygon to approach the circle way.
After practice, it has been improved, that is, the introduction of frequency compensation, can eliminate the error of speed control;
By feedback estimation of flux amplitude, eliminating the influence of stator resistance at low speed, the output voltage and current closed loop,
In order to improve the accuracy and stability of the dynamic.
But there are many control circuit, and no torque is introduced, so the system performance has not been improved.
Frequency converter is a power control device which uses the power of the power semiconductor device to change the power frequency to another frequency,
Can realize the asynchronous motor soft start, variable frequency speed regulation, improve the operation precision, change the power factor, over current / over voltage / overload protection and other functions.
The use of frequency converter motor is in order to speed, and reduce the starting current.
In order to produce a variable voltage and frequency,
The equipment to the power of the AC power conversion to DC (DC), the process is called rectification.
The direct current (DC) is transformed into alternating current (AC) and its scientific term is "inverter" (inverter).
General inverter is the DC power supply inverter for a certain fixed frequency and a certain voltage of the inverter.
For the inverter as the frequency adjustable, adjustable voltage inverter, we called the inverter.
Inverter output waveform is simulated sine wave,
Is mainly used in three-phase asynchronous motor speed control, and also called frequency governor.
For the variable frequency inverter, which is mainly uused in the testing equipment of instrument and meter,
To sort out the waveform, you can output the standard sine wave, called the inverter power supply FX2NC-100BPCB PDF datasheet.
The general inverter is 1520 times inverter price.
The main device called "inverter" because of the voltage or frequency of the inverter device ",
Therefore, the product itself is named "inverter", that is: inverter FX2NC-100BPCB PDF datasheet. "
Related products
MITSUBISHI
PLC
FX2NC-32MT-DSS
MITSUBISHI PLC FX2NC-32MT-DSS
Max input / output points: 32 points. Power s
MITSUBISHI
Connecting cable
FX2NC-10BPCB1
MITSUBISHI Connecting cable FX2NC-10BPCB1
Application: extended input module with input
MITSUBISHI
PLC
FX2NC-16MT-D/UL
MITSUBISHI PLC FX2NC-16MT-D/UL
Max input / output points: 16 points. Power s