Isolation: Photocoupler.
Zero cross function: --.
Indicator: NO.
Rated output load: 3 A at 4 to 48 VDC *2 .
Rated input voltage: 4 to 24 VDC.
New Models with International Standards.
Added to G3H Series (-VD in model number).
Same Profile as LY1 and LY2 Bi-power.
Relays.
Certified by UL, CSA, and VDE (models numbers with a suffix of “-VD”) OMRON Hybrid Power Relay PDF datasheet.
Socket type, same size as LY Power Relays
G9H Series
Operation indicator provided to confirm input,
(models numbers with “N” before the suffix). Terminal (Wire connection): Screw terminal.
Classification: Standard.
Latching lever (Test switch): No.
Rated input voltage: AC, 230V.
Global standard size, low profile slim.
I/O relay with width 6.2 mm OMRON Hybrid Power Relay PDF datasheet.
Realized about 25% lower profile than conventional.
products, contributing to further miniaturization of the control panel.
Realized opening and closing ability with one pole 6 A slim shape.
Micro load products for one pole 50 mA using Au-plated.
contacts for small load switching also available.
Since G2RV is a transparent case, confirming the state of,
the contact with the naked eye is possible, and easy to,
confirm abnormality on-site (installed location) OMRON Hybrid Power Relay PDF datasheet.
Screw terminal is also stocked to meet the screw type needs.
Mounted relay uses plug-in terminals that are difficult to,
bend when exchanging G9H Series PDF datasheet. Terminal (Wire connection): Push-In Plus Terminal.
Classification: Microloads.
Latching lever (Test switch): No.
Rated input voltage: AC/DC, 24V G9H Series PDF datasheet.
Global standard size, low profile slim.
I/O relay with width 6.2 mm.
Realized about 25% lower profile than conventional.
products, contributing to further miniaturization of the control panel.
Realized opening and closing ability with one pole 6 A slim shape.
Micro load products for one pole 50 mA using Au-plated G9H Series PDF datasheet.
contacts for small load switching also available.
Since G2RV is a transparent case, confirming the state of,
the contact with the naked eye is possible, and easy to,
confirm abnormality on-site (installed location).
Screw terminal is also stocked to meet the screw type needs.
Mounted relay uses plug-in terminals that are difficult to,
bend when exchanging. Input terminals: Compact slotted screw terminals (detachable).
Isolation method: Phototriaccoupler.
Zero cross function: Yes.
Operation indicator: Yes.
Alarm output: 2 outputs (Heater Burnout Detection,
SSR Short-circuit Failure Detection).
Applicable load (See note.): 2 to 35 A, 200 to 480 VAC.
A New-concept SSR with Built-in.
Current Transformer.
Heater Burnout and SSR Short.
circuit Failure Detection.
Built-in Current Transformer (CT) helps reduce wiring steps.
Detects the burnout of any one of a group of heaters.
Detects the burnout of 3-phase heaters.
Detectss SSR short-circuit failures G9H Series PDF catalog.
Error detection level can be easily set with a switch.
Mounts to a DIN track or with screws.
Three types of input terminals available: M3 terminals,
screwless clamp termiinals (detachable), or compact slotted,
screw terminals (detachable) OMRON Hybrid Power Relay PDF datasheet.
Certified for CSA and EN (TÜV).
The G3PF-2@@B-@@@ Series is UL certified.