LK Automation Limited
Home >> Download >> OMRON >> Catalog Download >> Guard Lock Safety-door Switch/D4SL-N-mounting Slide Key D4SL-N2DFA-N datasheet PDF catalog OMRON D4SL-N2DFA-N PDF datasheet

Guard Lock Safety-door Switch/D4SL-N-mounting Slide Key D4SL-N2DFA-N datasheet PDF catalog OMRON D4SL-N2DFA-N PDF datasheet

Product model: D4SL-N2DFA-N
Name: Guard Lock Safety-door Switch/D4SL-N-mounting Slide Key
Brand: OMRON
Sort: PDF datasheet
File language: English
File size: 6.12MB
Type of drive rod: roller plunger type.
Conduit size: single catheter type, M20.
Built in switch structure: slow motion (1NC/1NO).
Safety limit switch in accordance with global standard EN 50047.
The contact constitutes a complete variety, there is a single point of specification (1NC) and double contact specifications (1NC/1NO, 2NC) D4SL-N2DFA-N PDF catalog .
Forced open action structure.
The slow moving contact structure is adopted to ensure that the contact distance is 4mm D4SL-N2DFA-N
Elevator and escalator can be used. Actuator: Arm lever.
Conduit size: 1-conduit; Pg13.5.
Built-in switch mechanism: 3NC (Slow-action).
Compact, Plastic-body Safety-door.
Hinge Switch Designed for Saving.
Space in Machines and Other D4SL-N2DFA-N PDF catalog .
Equipment.
Lineup includes three contact models with 2NC/1NO and.
3NC contact forms in addition to the previous contact forms.
1NC/1NO, and 2NC. Models with MBB contacts are also available.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads. Actuator type: Roller lever.
Compact Vertical Models Sized for Asian.
Standards D4SL-N2DFA-N PDF catalog .
Compact new design approximately 1/3 the size of OMRON,
vertical Limit Switches.
Structure enables the terminal section to be fully opened for,
easy wiring.
RoHS complaint.
Degree of protection: IP65. Specifications: Inputs; NPN (+ common); 8 points OMRON D4SL-N2DFA-N PDF datasheet.
I/O connections: M3 Screw terminals.
Rated internal circuit power supply voltage:
Supplied from the communications connector OMRON D4SL-N2DFA-N PDF datasheet.
Rated I/O power supply voltage: 24 VDC.
Allows I/O Expansion with Transistor Terminals.
Wide variety of data, such as maintenance system data,
can be collected without affecting the productivity,
of the control system.
Valuable information can be collected,
and managed through the network, including information,
on the communications power supply OMRON D4SL-N2DFA-N PDF datasheet.
voltage levels, Unit wear and tear,
and equipment operating information.
Expansion via Expansion I/O Units.
With no communications baud rate settings,
required and detachable terminal blocks,
maintenance is easier. Actuator: Roller plunger (Metal roller).
Cable length: 1 m.
Pull-outing direction of cable: Horizontal.
Built-in switch: 2NC (slow-action).
Smallest Class of Safety Limit Switchees the World D4SL-N2DFA-N datasheet.
The world''s smallest limit switch with a direct opening,
mechanism (four-contact construction model).
High-sensitivity safety limit switch.
Built-in switches with two- or four-contact construction are avaailable D4SL-N2DFA-N PDF catalog .
Degree of protection: IP67.
Conforms to EN115-1, EN81-1 and EN81-2.
(slow-action models only).
Certified standards: UL, EN (TÜV), and CCC.