Control supply voltage: 220 VAC; With voltage fluctuation compensation.
Operating current: 32 to 80 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal OMRON Single-phase Voltage Relay PDF datasheet.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out
K8AK-VS2 100-240VAC
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with both single-phase and three-phase heaters.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage OMRON Single-phase Voltage Relay PDF datasheet. Supply voltage: 24 VDC.
Input type: DC voltage, DC current, or NPN input.
Output type: Judgement output, 2 relay contact outputs (SPST-NO) Normally energized relays (See note.);
Data transmission output, DC voltage (0 to 5 V, 1 to 5 V, 0 to 10 V).
1/32 DIN Digital Panel Meter for Downsizing.
Equipment and Control Panels.
Compact size: 48 x 24 x 82 (W x H x D) OMRON Single-phase Voltage Relay PDF datasheet.
Multi-input compatible: DC voltage/current, rotary pulse.
Two display colors (switchable): green/red.
Selectable outputs.
CE marking and UL/CSA approval.
Splash-proof construction (NEMA4X: equivalent to IP66) K8AK-VS2 100-240VAC PDF datasheet. Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (HOLD, RESET) equipped with.
External power supply DC12V80mA K8AK-VS2 100-240VAC PDF datasheet.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
Relay contact: H; PASS1c, L, each 1c.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
Measurement of 2 points through the speed, time, or cycle of the digital time interval table.
Action determine the color, can switch the green / Red 2 kinds of color display K8AK-VS2 100-240VAC PDF datasheet.
Measurement of wide range of pulse interval time.
Measuring, calculating and displaying the pulse interval between 2 points.
Pulse interval measurement range, the maximum can be measured from 10ms to 320Three-phase Phase-sequence Phase-loss.
Relay Using Voltage Detectiion Method K8AK-VS2 100-240VAC PDF catalog.
Greater resistance to inverter noise.
Distinguishes between correct phases, phase sequence, and phase,
loss when power is turned ON.
Supports phase loss detection when the motor is operrating OMRON Single-phase Voltage Relay PDF datasheet.
5 A (resistive load) at 250 VAC, DPDT x 1.
Output status can be monitored using LED indicator.
Ideal to prevent reverse operation of motors.