LK Automation Limited
Home >> Download >> MITSUBISHI >> Catalog Download >> LD75P1-CM PDF datasheet MITSUBISHI LD75P1-CM datasheet PDF catalog

LD75P1-CM PDF datasheet MITSUBISHI LD75P1-CM datasheet PDF catalog

Product model: LD75P1-CM
Name: Positioning module
Brand: MITSUBISHI
Sort: PDF datasheet
File language: English
File size: 12.21MB
"Universal output function: leakage type.
Program capacity: 260K step.
Basic operations processing speed: 9.5ns.
Communication interface: USB/Ethernet.
Program capacity: 20K step.
Control mode: stored procedure repeated operation.
Input / output points: 4096 points.
End cap.
High precision PWM control of the highest 200kHz MITSUBISHI LD75P1-CM PDF catalog.
In the PWM output mode, by setting the ON time and cycle time,
The duty cycle can be changed, and the minimum cycle time is 5 s LD75P1-CM
In addition to lighting dimming control, simple motor control and heater control,
Can also be used to require high resolution detection equipment, such as a wide range of oscillators.
CPU built-in functions can be easily set through programming tools MITSUBISHI LD75P1-CM PDF catalog.
The built-in I/O function settings can be easily carried out through the parameters of the programming tool.
5 s units can be used for high precision workpiece measurement in pulse measurement mode,
Can be used with a minimum of 5 s units of the input signal of the ON/OFF time (the shortest 200 s) for high precision measurement.
For example, after measuring the ON time of the sensor input,
The "moving speed" and "length" of the workpiece can be accurately calculated " MITSUBISHI LD75P1-CM PDF catalog. "Output points: 16 points.
Output form: bidirectional thyristor output.
Rated output voltage: AC100 ~ 240V.
Max load current: 0.6A/1 point.
Common way: 16 point / public end.
Input / output occupied points: 16 points (I/O distribution: output 16 points).
External wiring connection: 18 point terminal.
1, the switch quantity acquisition and switch control and RS-485 bus are isolated from each other, and isolated from the whole system.
2, the power supply line has anti reverse connect function, once the wrong power line,
Will automatically cut off the power to protect the entire module is not damaged.
With over-voltage protection function, when the voltage is too high, automatic disconnection,
Protecting the entire module is not damaged.
3, RS-485 interface with 600W lightning protection and surge protection function, with 3000V photoelectric isolation LD75P1-CM PDF datasheet.
4, the use of Modbus protocol, good general, can be very convenient and other systems,
Customers can also according to their own personal needs, custom related agreements, convennient and flexible LD75P1-CM PDF datasheet.
5, communication lines using RS-485 bus, support for multiple modules in parallel use,
Easy to expand the system, good scalability.
Related products
MITSUBISHI
Positioning module
LD75D1-CM
MITSUBISHI Positioning module LD75D1-CM
Differential output. Axis of control: 1. Maxi
MITSUBISHI
Positioning module
LD75P2-CM
MITSUBISHI Positioning module LD75P2-CM
Open collector output. Axis of control: 2. Ma
MITSUBISHI
Positioning module
LD75D4-CM
MITSUBISHI Positioning module LD75D4-CM
Differential output. Axis of control: 4. Maxi
MITSUBISHI
Positioning module
LD75P1-CM
MITSUBISHI Positioning module LD75P1-CM
Open collector output. Axis of control: 1. Ma