Product model: A1S32B
Name: CPU base plate
Brand: MITSUBISHI
Sort: PDF datasheet
File language: English
File size: 1.60MB
Description: GI type optical fiber cable with (combination of 2 sets of use), the maximum number of connections: 2, the longest transmission distance: 2000m.
Spare 5 products for different purposes.
Thin waterproof type relay hub.
Extension of star type wiring and main line length, waterproof structure A1S32B PDF datasheet.
Spring clip terminal type relay hub.
Star type wiring, length of the main line, spring clamping terminal table type A1S32B
Relay appliance (T branch) unit.
Extension of T type branch and trunk length.
Relay unit in light.
In the presence of interference in the environment of the wiring, the length of the trunk line.
Relay unit in space light.
Communication between linear moving bodies. Master / local station A1S32B PDF datasheet.
QnACPU use.
According to the control requirements of the system, using the appropriate design method to design MITSUBISHI PLC program.
Procedures to meet the requirements of system control as the main line,
Write one by one to achieve the control function or the sub task of the program,
Gradually improve the functions specified by the system.
MITSUBISHI PLC initialization procedure A1S32B PDF datasheet. After MITSUBISHI PLC on power, the general need to do some of the initial operation,
In order to start making necessary preparations, to avoid the wrong operation of the system.
The main contents of the initialization program are: to some data area, counter and so on,
Data needed to restore some of the data area,
Set or reset some relays,
For some initial state display, etc.. "Input voltage range: AC100 ~ 120V.
Output voltage: DC24V.
Output current: 0.6A.
Relay output interface circuit of PLC
Working process: when the internal circuit output digital signal 1,
There is a current flowing through, the relay coil has a current, and then the normally open contact is closed,
Provide load current and voltage.
When the internal circuit outputs a digital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is disconnected from the load.
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action.
I/O points is an important indicator of PLC.
Reasonable selection of I/O points can not only satisfy the control requirements of the system,
And the total investment of the system is the lowest.
The input and output points and types of PLC should be determined accordding to the analog quantity and switch quantity of the controlled object,
Generally an input / output element to take up an input / output point A1S32B PDF catalog.
Taking into account the future adjustment and expansion,
In general should be estimaated on the total number of points plus the amount of spare 20%~30% A1S32B PDF catalog.
The following describes the centralized control system I/O points of the estimate.
Related products
MITSUBISHI
DC source type input module
A1SX80-S2
MITSUBISHI DC source type input module A1SX80-S2
Type of input: DC source. Input points: 16 po
MITSUBISHI
Ethernet module
A1SJ71QE71N-B2
MITSUBISHI Ethernet module A1SJ71QE71N-B2
10BASE2. Q mode. MITSUBISHI PLC is the main p
MITSUBISHI
Extended bottom plate
A1S68B
MITSUBISHI Extended bottom plate A1S68B
8 slots. Can e installed in the power supply