MITSUBISHI AJ35TJ-48DT PDF datasheet AJ35TJ-48DT datasheet PDF catalog

Product model: AJ35TJ-48DT
Name: DC input / transistor output module
Brand: MITSUBISHI
Sort: PDF datasheet
File language: English
File size: 7.99MB
Output points: 16 points.
Voltage: DC24V/AC240V, 2A/1 point, 8A/1 public end.
OFF leakage current: 0.1mA.
Output type: relay output.
Response time: 12ms.
8 point /1 a public side.
20 point terminal station.
With the surge absorber.
CE certification.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor AJ35TJ-48DT PDF datasheet AJ35TJ-48DT
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc AJ35TJ-48DT PDF datasheet. .
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process AJ35TJ-48DT PDF datasheet.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points. Three remote components can be connected to the CC-LINK system.
Remote I/O: refers to the field components that require only ON/OFF control,
Such as digital I/O or pneumatic valve, etc..
In this type of communication can only be carried out in the bit data.
Remote components: the field components that require processing of register data,
For example analog I/O and counter, etc..
In this type of component, in addition to the bit data can be carried out in the register data communication.
Intelligent remote: this type of element refers to the actions that allow the master station or other station to access,
To collect data and control the local PLC station,
GOTS and programmer interface unit are of this type.
PLC is the use of " sequential scanning, and constantly circulating " way to work.
That is, in the operation of CPU, PLC according to the user according to the control requirements of the coexistence of the user in the memory of the program,
According to the instruction sequence number (or address number) for periodic cyclic scan, such as no jump instruction,
From the first instruction to the user program execution sequence one by one, until the end of the program,
And then return to the first command, start the next round of the new scan, in the process of each scan,
Also complete the sampling of the input signal and the output status of the refresh and other work.
PLC is the use of " sequential scanning, and constantly circulating " way to work.
That is, in the operation of CPU, PLC according to the user according to the control requirements of the coexistence of the user in the memory of the program,
According to the instruction sequence number (or address nnumber) for periodic cyclic scan, such as no jump instruction,
From the first instruction to the user program execution sequence one by one, until the end of the program,
And then return to the first command, start the next rround of the new scan, in the process of each scan,
Also complete the sampling of the input signal and the output status of the refresh and other work AJ35TJ-48DT PDF catalog AJ35TJ-48DT PDF catalog.
Related products
MITSUBISHI
Analog module
AJ35T-M08B-L
MITSUBISHI Analog module AJ35T-M08B-L
Analog channel: 8 channels. Input / output r
MITSUBISHI
AC100V input module
AJ35TJ-8A
MITSUBISHI AC100V input module AJ35TJ-8A
AC input points: 8 points. Input voltage and
MITSUBISHI
Relay output module
AJ35TB1A-8R
MITSUBISHI Relay output module
 AJ35TB1A-8R
Output points: 8 points. Output voltage and c
MITSUBISHI
Silicon controlled output module
AJ35TJ-8S1
MITSUBISHI Silicon controlled output module
 AJ35TJ-8S1
Output points: 8 points. Output voltage and c