Actuator: Arm lever.
Conduit size: 1-conduit; Pg13.5.
Built-in switch mechanism: 1NC/1NO MBB (Slow-action).
Compact, Plastic-body Safety-door.
Hinge Switch Designed for Saving.
Space in Machines and Other.
Equipment.
Lineup includes three contact models with 2NC/1NO and.
3NC contact forms in addition to the previous contact forms D4C-1731 datasheet.
1NC/1NO, and 2NC. Models with MBB contacts are also available
D4C-1731
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads. Actuator: One-way roller arm lever (horizontal).
Conduit size: 1-conduit; Pg13.5.
Built-in switch mechanism: 3NC (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards D4C-1731 datasheet.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only) D4C-1731 datasheet.
Certified standards: UL, EN (TÜV), and CCC. Receptacle box: G 1/2 Conduit.
Indicator: With LED indicator (DC).
Actuator: Roller lever *1, High-sensitivity.
The Limit Switch with Better Seal,
Shock Resistance, and Strength.
A double seal on the head, a complete gasket cover, and,
other features ensure a better seal (meets UL NEMA 3, 4, 4X, 6P, 12, 13).
Wide standard operating temperature range:
-40°C to +100°C (standard type).
Models with fluoro-rubber available for greater resistance to chemicals.
Block mounting method also reduces downtime for maintenance.
DPDT, double-break models available for complex operations.
Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved model.) Name: Safety I/O Terminals.
No. of I/O points: Safety inputs: 8, safety outputs (semiconductor): 8,
test outputs: 4.
Distributed Safety Terminals That.
Reduce Wiring.
Lineup includess four models to accommodate various,
I/O types and number of I/O points D4C-1731 PDF datasheet.
Monitor the safety system from Standard Controllers,
across the network.
EN954-1 (Cat.4), ISO13849-1 (PLe),
and IEC 61508 SIL3 certification.
The DST1-XD0808SL-1 also supports logic operation,
functions for high-speed processing in applications,
requiring partial stopping of the safety system D4C-1731 PDF datasheet.