Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use E2C-X5A 3M PDF datasheet.
Event entry point: 4
E2C-X5A 3M
Transfer output: output (using control output).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance E2C-X5A 3M PDF datasheet.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc E2C-X5A 3M PDF datasheet. , can be a key operation. Classification: Exclusive Models.
Description: Crimping terminals.
Temperature range (See note 3.): 0°C to 300°C.
Element type: K (CA) J (IC).
Conductor type: Grounded type.
Class: 2 (0.75).
Protective tubing material: --.
Terminal type: Exposed lead wires.
Page: 21.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Control output 1: Voltage output.
Control output 2: --.
Auxiliary output: Three.
Communications: --.
Heater burnout: One.
Event inputs: Four.
Power supply voltage: 100 to 240 VAC.
Large White PV Display That’s Easier to Read.
Easy to Use, from Model Selection to Setup and Operattion E2C-X5A 3M PDF catalog.
A Complete Range of I/O Capacities,
Functions, and Performance.
Handles More Applications.
The white PV display with a height of 15.2 mm improves visibility.
High-speed sampling at 50 ms.
Short body with depth of oonly 60 mm E2C-X5A 3M PDF catalog.
Easy connections to a PLC with programless communications.
Use component communications to link Temperature,
Controllers to each other.