Sensing method: Capacitive.
Applicable pipe diameters: 12 to 26 mm.
Output configuration/Operation mode: NPN open-collector output, NO.
Liquid Level Sensor That Is.
Unaffected by the Color of the Pipe or.
Liquid.
Mount to bypass pipes.
Fit a wide range of pipe diameters: 8 to 11 mm or 12 to 26 mm E2FM-X10C1-M1 datasheet.
Built-in Amplifiers to save space. Size: 48 x 24mm.
Control output 1: relay output
E2FM-X10C1-M1
Control output 2:--.
Auxiliary output: 1 points.
Power supply voltage: AC100 ~ 240V.
Terminal type: PUSH-IN fastening terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: -.
Event input: -.
A small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance E2FM-X10C1-M1 datasheet.
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc..
Although the small size, but also through the character of the high 10.5mm white PV display to achieve high recognition.
The terminal stage is adopted to disassemble and assemble the structure, which improves the maintenance performance E2FM-X10C1-M1 datasheet.
The connection method can be selected from a screw terminal and a PUSH-IN fastening terminal.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication.
The use of electric communication conversion Village (sold separately) connected to the computer after,
No power connection can be set.
It can be easily set by CS-Thermo (sold separately). Sensing method: Convergent-reflective.
Connection method: Pre-wired (2 m).
Sensing distance: 5 to 30 mm.
Operation mode: Dark-ON.
Model: PNP output.
Makes Mounting and Installation Simpler and Smoother.
Suitable for Applications in the Rechargeable Battery Industry. E3F3-R16M detection methods: Regression reflection type,
Lead extraction: CN M12,
Type: metal appearance; NPN output,
Threaded cylindrical photoelectric sensor, built-in amplifier,
Photoelectric sensor with proximity sensor appearance
High anti interference with optoelectronic -IC technologySize: 96 x 96mm.
Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 4.
Transfer output: output (special terminal).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RRUN/STOP, alarm), interactive display PV/SV E2FM-X10C1-M1 PDF datasheet.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E2FM-X10C1-M1 PDF datasheet.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.