The main body: terminal type, temperature input type.
Type: control output 2 point type (power AC/DC24V).
Shell color: black.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver)
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function E39-S76B PDF catalog
E39-S76B
Event input points: -.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement E39-S76B PDF catalog.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay. Type: Unshielded.
Appearance: Screw, M18 × 46 E39-S76B PDF catalog. 3 mm.
Sensing distance: 7 mm.
Repeat accuracy: 5 μm.
Cable specification: Standard.
Proximity Sensor with Separate.
Amplifier Enables Easily Making High.
precision Sensitivity Settings.
Wide variety of Sensor Heads to select according to the,
application OMRON Mounting Brackets PDF catalog. Flexible cables are used between Preamplifiers,
and Amplifier Units of the Sensor Heads.
High resistance to changes in ambient temperature OMRON Mounting Brackets PDF catalog.
Temperature characteristics of 0.08%/°C (for 5.4-dia. models).
Make simple and reliable detection settings with micron,
level precision using the teaching function.
Check the sensing excess gain level on the digital display.
Support for high-precision positioning and screening with,
fine positioning to maximize variations OMRON Mounting Brackets PDF catalog.
The E2C-EDA0 supports an EtherCAT Sensor,
Communications Unit or CompoNet Sensor,
Communications Unit. Control output 1: Voltage output.
Auxiliary output: Two.
Communications: RS-485.
Heater burnout: One.
Event inputs: --.
Power supply voltage: 24 VAC/VDC.
Large White PV Display That’s Easier to Read.
Easy to Use, from Model Selection to,
Setup and Opeeration E39-S76B PDF datasheet.
A Complete Range of I/O Capacities,
Functions, and Performance.
Handles More Applications.
The white PV display with a height of 15.2 mm improves visibility.
High-speed sampling at 50 ms.
Short body with depth of only 60 mm E39-S76B PDF catalog.
Easy connections to a PLC with programless communications.
Use component communications to link Temperature.
Controllers to each other.