Sensor type: Diffuse-reflective.
Sensing distance: 1 m.
Connection method: M12 connector.
Model: NPN output.
A new generation in sensing performance.
Simplicity.
Simple selection.
Simple installation.
One family for all.
All standard applications covered.
A wide variety of models.
Models designed for special applications E5EN-HSS2HH02BD-FLK PDF catalog.
Non-stop detection.
High quality and reliability
E5EN-HSS2HH02BD-FLK
High EMC protection.
High light immunity.
Robust and waterproof housing. Item: Advanced models, ATC function.
Functions: ATC (Active Threshold Control).
Model: NPN output.
Variable Laser Beam for Spot, Line, or Area Detection.
Long-distance detection (diffuse reflective: 1 m, retro-reflective: 7 m).
Beam shape selectable from spot, line, and area types to match various applications E5EN-HSS2HH02BD-FLK PDF catalog.
Adjustable spot diameter.
Adjustable optical axis.
The E3DC-LDA0, which supports the EtherCAT Sensor.
Communications Unit and the CompoNet Sensor.
Communications Unit, is also included in product lineup. Case color: Black.
Control output: Current output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1 E5EN-HSS2HH02BD-FLK PDF catalog.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: 2.
Transfer output *2: Transfer output using control output.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance OMRON High performance temperature controller PDF catalog. Improved Indication Accuracy,
and Preventive Maintenance Function OMRON High performance temperature controller PDF catalog.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks OMRON High performance temperature controller PDF catalog.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperaturee Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E5EN-HSS2HH02BD-FLK PDF datasheet.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E5EN-HSS2HH02BD-FLK PDF catalog.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.