Number of phases: Single-phase.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC.
Zero cross function: Yes.
Applicable load: 25 A, 100 to 240 VAC.
Compact, Slim-profile SSRs with Heat,
Sinks. Models with No Zero Cross for,
a Wide Range of Applications G2RV-SR700-AP DC24 PDF catalog.
RoHS compliant.
Models also available with no zero cross,
Surge pass protection improved surge dielectric strength for,
output currents
G2RV-SR700-AP DC24 (OMRON testing).
Compact with a slim profile.
Mount to DIN Track or with screws.
Conforms to UL, CSA, and EN standards (TÜV certification). Isolation: Photocoupler.
Zero cross function: Yes.
Indicator: Yes(Yellow).
Applicable output load (See note 1 G2RV-SR700-AP DC24 PDF catalog. ): 90 A at 200 to 480 VAC (See note 2.).
Rated input voltage: 100 to 240 VAC.
Wide Lineup of General-purpose Solid State.
Relays with Applicable Loads of 5 to 90 A.
AC Output Relays with 75-A and 90-A output currents have been,
added to the G3NA Series.
All models feature the same compact dimensions to provide a,
uniform mounting pitch.
Built-in varistor effectively absorbs external surges G2RV-SR700-AP DC24 PDF catalog.
(except G3NA-D210B).
Operation indicator enables monitoring operation.
Protective cover for greater safety.
Standard models certified by UL and CSA and -UTU models by TÜV.
(except G3NA-410B, G3NA-420B, and G3NA-440B(-2)) OMRON Slim I/O Relay PDF catalog. Safety outputs: Instantaneous, DPST-NO; OFF-delayed, DPST-NO.
Auxiliary outputs: 1 (Solid-state).
Max. OFF-delay time: 30 s OMRON Slim I/O Relay PDF catalog.
Rated voltage: 24 VDC.
Complete line-up of compact units,
including OFF-delayed safety output models.
17.5 or 22.5 mm width to save mounting space.
Simple wiring using screw-less terminals.
Easy maintenance with status indicators.
One unit for various safety devices, from contact input to PNP input OMRON Slim I/O Relay PDF catalog. Input capacity: 16 points.
Rated current (ON current): 0.5 A/output,
4.0 A/common.
Internal I/O common: NPN.
Residual voltage: 1.2 V max.
(0.5 ADC, between each output,
terminal and the G terminal)
Leakage current: 0.1 mA max.
ON delay: 0.5 ms max.
OFF delay: 1.5 ms max.
Number of circuits per common:
8 points/common.
Output indicators: LED display (yellow).
Isolation method: Photocoupler isolation.
I/O power supply method: Supply by I/O power supply.
Output device supply current: 100 mA/point.
Unit power supply current consumption: 90 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
I/O power supply current consumption: 5 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
Weight: 370 g max.
Expansion functions: No.
Output handling for communications errors:
Select either hold or clear.
Short-circuit protection function: No.
A common terminal is provided for each contact.
It eliminate the needs for relay terminal blocks.
It is unnecessary to share the common terminal,
among multiple contacts.
Easyy-to-find wiring locations G2RV-SR700-AP DC24 PDF datasheet.
Detachable screw terminal block facilitates the maintenance.
Input response time can be switched for high-speed processing.
Selectable node address setting methods: setting with rotary,
switch and with tool software G2RV-SR700-AP DC24 PDF catalog.
When setting the nodes with rotary switch, setting is easy and,
node identification becomes possible for maintenance.