Cable with connector (1 to 3) /G79-_C-_-_.
L size: A, 3000mm; B, 2750mm; C, 2500mm.
Input use
Cable and loose wire cable with loose wire pressing connecting terminal,
Connector cable, MITSUBISHI motor produced PLC connection cable. Isolation: Photocoupler.
Zero cross function: Yes.
Indicator: Yes(Yellow) G3PA-220B-VD DC5-24 PDF datasheet.
Applicable output load (See note 1.): 90 A at 200 to 480 VAC(See note 2
G3PA-220B-VD DC5-24).
Rated input voltage: 5 to 24 VDC.
Wide Lineup of General-purpose Solid State.
Relays with Applicable Loads of 5 to 90 A.
AC Output Relays with 75-A and 90-A output currents have been,
added to the G3NA Series.
All models feature the same compact dimensions to provide a,
uniform mounting pitch.
Built-in varistor effectively absorbs external surges G3PA-220B-VD DC5-24 PDF datasheet.
(except G3NA-D210B).
Operation indicator enables monitoring operation.
Protective cover for greater safety.
Standard models certified by UL and CSA and -UTU models by TÜV.
(except G3NA-410B, G3NA-420B, and G3NA-440B(-2)). Classification: Relay .
Structure: 4 poles.
Contact configuration: 4PST-NO.
Rated Voltage: 12, 24 VDC.
Compact Electromagnetic Contactors That G3PA-220B-VD DC5-24 PDF datasheet.
Switch 40 A at 440 VAC.
One pole carries 40 A.
UL 508 and UL 840 NC contacts (resistive 40 A 480 VAC, 60 Hz, 80,000 operations).
EN 60947-4-1 NC contacts (AC1 40 A 440 VAC, 50/60 Hz, 80,000 operations).
Ideal for supply power to industrial inverters, servo drivers, and other devices,
and switching power to motors and other equipment.
The maximum load capacity of 160 A when using 4-pole parallel connections.
EN 60947-4-1 certification for mirror contact mechanism obtained by combining,
the Relay with an Auxiliary Contact Block.
Conforms to European PV standard (VDE0126).
Approx. 30% less operation noise than a standard electromagnetic contactor.
(Approx. 100 dB reduced to approx. 70 dB.)
Approx. 50% the volume of a standard electromagnetic contactor,
to help downsize control panels.
According to OMRON investigation of IIEC-AC1 50 A specifications. Refer to Safety Precautions for All Solid State Relays.
Allows 2-wire Switching of 3-phase Power.
Ideal for 2-wire switching of 3-phase heaters.
Improve ease of operation. Terminal (wire connection): Screw terminal.
Applicable output load: AC load.
Zero cross function: Yes.
Rated input voltage: AC 200V.
Global standard size,
low profile slim I/O relay with width 6.2 mm,
slim I/O solid state relay.
Realized about 25% lower profile than conventional,
products, contributing to further miniaturization of the,
control panel.
Push-In Plus terminal blocks are used to save wiring work,
in comparison with conventional screw terminals.
(Wiring time is reduced by 60%* in comparison with,
traditional screw terminals.).
No screw looosening means maintenance-free application,
realizing high reliability G3PA-220B-VD DC5-24 PDF catalog.
Hand-free structure that holds an inserted flat-blade,
screwdriver to achieve easier wiring work for stranded wires.
Screw terminal is also stocked to meet the screw type needs G3PA-220B-VD DC5-24 PDF catalog.
Mounted relay or solid-state relay has a plug-in terminal.
that is difficult to bend at the time of exchange.