Number of phases: Three-phase.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC.
Zero cross function: Yes.
Type: DIN track mounting *2.
Applicable load: 35 A, 100 to 240 VAC.
Number of pole: 2.
Compact, Slim-profile SSRs with Heat Sinks G3PE-245B-2N DC12-24 PDF datasheet.
Solid State Contactors for Three-phase.
Heaters Reduced Installation Work
G3PE-245B-2N DC12-24
with DIN Track Mounting.
RoHS compliant.
Surge pass protection improved surge dielectric strength,
for output currents. (OMRON testing).
Slim design with 3-phase output and built-in heat sinks.
DIN Track mounting types and screw mounting types are available.
All DIN Track mounting types mount to DIN Track.
(applicable DIN Track: TR35-15Fe (IEC 60715)) G3PE-245B-2N DC12-24 PDF datasheet.
Conforms to UL, CSA, and EN standards (TÜV certification). Name: Multi-channel Power Controller.
Number of control channels: 4.
Heater burnout detection: Supported.
Load power supply voltage: 100 to 240 VAC.
Optimum Cycle Control for High-precision.
Control with Low Noise.
Smaller than a Normal Power Controller.
Enables low-noise power control in combination with zero-cross G3PE-245B-2N DC12-24 PDF datasheet.
SSRs. (See note.).
One Controller can control up to 8 SSRs.
RS-485 communications to set manipulated variables and,
heater burnout detection. The Smart FB Library for the G3ZA,
can also be used.
CE Marking.
Main Upgraded Functions.
Soft-start function added for lamp heaters.
Three-phase optimum cycle control added for three-phase heaters.
Combining with special CT for150-A current detection.
Note: The G3ZA must be used in combination with an SSR without the,
zero cross function when the soft-start function is used. Terminal (wire connection): Push-In Plus Terminal.
Applicable output load: DC load.
Zero cross function: --.
Rated input voltage: AC/DC 48V.
Global standard size,
low profile slim I/O relay with width 6.2 mm,
slim I/O solid state relay.
Realized about 25% lower profile than conventional,
products, contributing to further miniaturization of the,
control panel.
Push-In Plus terminal blocks are used to save wiring work,
in comparison with conventional screw terminals.
(Wiring time is reduced by 60%* in comparison with,
traditional screw terminals.).
No screw looosening means maintenance-free application,
realizing high reliability G3PE-245B-2N DC12-24 PDF catalog.
Hand-free structure that holds an inserted flat-blade,
screwdriver to achieve easier wiring work for stranded wires.
Screw terminal is also stocked to meet the screw type needs G3PE-245B-2N DC12-24 PDF catalog.
Mounted relay or solid-state relay has a plug-in terminal.
that is difficult to bend at the time of exchange.