Safety outputs: Instantaneous, --; OFF-delayed, 4 PST-NO.
Auxiliary outputs *1: 1(Semiconductor).
OFF-delay time: *2.
Rated voltage: 24 VDC.
Terminal block type: Screw terminals.
Logical AND Function Adds Flexibility to I/O Expansion.
Facilitates partial or complete control system setup.
Solid-state outputs (excluding Expansion Units) G3RV-SR500-AL AC200 PDF catalog.
Detailed LED indications enable easy diagnosis
G3RV-SR500-AL AC200
TÜV SÜD certification for compliance,
with IEC/EN61508 (SIL3), EN ISO13849-1 (PLe/Safety Category 4).
Approved by UL and CSA.
New unit joins the Series with the following two additional features:
-OFF-delay time of up to 150 seconds can be set.
-Two logical AND connection inputs. Number of phases: Three-phase G3RV-SR500-AL AC200 PDF catalog.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC.
Zero cross function: Yes.
Type: Externally attached heat sinks.
Applicable load: 45 A, 100 to 240 VAC.
Number of pole: 2.
Compact, Slim-profile SSRs with Heat Sinks.
Solid State Contactors for Three-phase.
Heaters Reduced Installation Work.
with DIN Track Mounting.
RoHS compliant G3RV-SR500-AL AC200 PDF catalog.
Surge pass protection improved surge dielectric strength,
for output currents. (OMRON testing).
Slim design with 3-phase output and built-in heat sinks.
DIN Track mounting types and screw mounting types are available OMRON Slim I/O Relay PDF catalog.
All DIN Track mounting types mount to DIN Track.
(applicable DIN Track: TR35-15Fe (IEC 60715)).
Conforms to UL, CSA, and EN standards (TÜV certification) OMRON Slim I/O Relay PDF catalog. Safety outputs: Instantaneous, DPST-NO; OFF-delayed, DPST-NO.
Auxiliary outputs: 1 (Solid-state).
Max. OFF-delay time: 5 s.
Rated voltage: 24 VDC.
Complete line-up of compact units,
including OFF-delayed safety output models.
17.5 or 22.5 mm width to save mounting space OMRON Slim I/O Relay PDF catalog.
Simple wiring using screw-less terminals.
Easy maintenance with status indicators.
One unit for various safety devices, from contact input to PNP input. Input capacity: 16 points.
Internal I/O common: PNP.
ON voltage: 15 VDC min.
(between each input terminal and the G terminal)
OFF voltage: 5 VDC max.
(between each input terminal and the G terminal)
OFF current: 1.0 mA max.
Input current: 6.0 mA max./input (at 24-VDC);
3.0 mA min./input (at 17-VDC).
ON delay: 0.1 ms max.
OFF delay: 0.2 ms max.
Input filter value: Without filter, 0.5 ms, 1 ms,
2 ms, 4 ms, 8 ms, 16 ms, 32 ms (Default setting: 1 ms).
Number of circuits per common: 16 inputs/common.
Input indicators: LED display (yellow).
Isolation method: Photocoupler isolation.
I/O power supply method: Supply by I/O power supply.
Unit power supply current consumption: 90 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
I/O power supply current con sumption: 5 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
Weight: 180 g max.
Expansion functions: Enabled.
Short-circuit protection function: No.
High-speed digital I/O terminal with the,
screw type terminal block for EtherCAT,
communications.
Detachable screw terminal block facilitates,
the maintenance.
The expansion unit can be connected.
(One expansion unit per one I/O tterminal unit G3RV-SR500-AL AC200 PDF datasheet. )
Input/output point can be flexibly increased,
depending on the system.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary sswitch and with tool software G3RV-SR500-AL AC200 PDF catalog.
When setting the nodes with rotary switch,
setting is easy and node identification becomes,
possible for maintenance.