Isolation: Photocoupler.
Zero cross function: Yes.
Indicator: Yes(Yellow).
Applicable output load (See note 1.): 75 A at 200 to 480 VAC(See note 2.).
Rated input voltage: 5 to 24 VDC.
Wide Lineup of General-purpose Solid State.
Relays with Applicable Loads of 5 to 90 A.
AC Output Relays with 75-A and 90-A output currents have been,
added to the G3NA Series G3RV-SR500-D AC100 PDF datasheet.
All models feature the same compact dimensions to provide a,
uniform mounting pitch
G3RV-SR500-D AC100
Built-in varistor effectively absorbs external surges.
(except G3NA-D210B).
Operation indicator enables monitoring operation.
Protective cover for greater safety.
Standard models certified by UL and CSA and -UTU models by TÜV.
(except G3NA-410B, G3NA-420B, and G3NA-440B(-2)) G3RV-SR500-D AC100 PDF datasheet. Safety outputs: Instantaneous, 4PST-NO; OFF-delayed, --.
Auxiliary outputs: 1 (Solid-state).
Max. OFF-delay time: --.
Rated voltage: 24 VDC.
Complete line-up of compact units,
including OFF-delayed safety output models.
17.5 or 22.5 mm width to save mounting space.
Simple wiring using screw-less terminals.
Easy maintenance with status indicators.
One unit for various safety devices, from contact input to PNP input G3RV-SR500-D AC100 PDF datasheet. I/O classification: Output.
I/O points: 16.
Internal I/O circuit common: NPN (+ common).
Rated voltage: 12 VDC, 24 VDC.
Single Cable Connection to PLC Means.
Space is Saved and Less Control Panel.
Wiring is Required.
Compact size: 182 (W) 85 (D) 68 (H) mm,
(8-point Output Block width is 102 mm).
Connects to the PC through the connecting cable,
(G79 Series) and connector, and requires only a,
snap-in operation.
Surge suppressor circuit built-in.
Immediate recognition of I/O signal status using,
LED operation indicators.
G3TA I/O Solid-state relay can be mounted instead,
of G7T.
Mounts easily on a DIN track.
Approved by UL, CSA (except for G7TC-OC16-1). Internal I/O common: NPN.
I/O indicators: LED display (yellow). 140 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
e-CON Connector insertion durability: 50 times.
Weight: 220 g max.
Expansion functions: No.
Short-circuit protection function: Available at input,
section only (Operates at 50 mA/point min.)
Easy wiring using industry standard,
e-CON connectors.
Special wiring tool is not necessary.
Digital I/O terminal with industry,
standard e-CON connectors.
A common terminal is providedd for,
each connector G3RV-SR500-D AC100 PDF catalog.
The I/O terminal and the sensors can,
be connected directly.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary,
sswitch and with tool software G3RV-SR500-D AC100 PDF catalog.
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance.