Terminal (wire connection): Push-In Plus Terminal.
Applicable output load: DC load.
Zero cross function: --.
Rated input voltage: AC/DC 48V.
Global standard size,
low profile slim I/O relay with width 6.2 mm,
slim I/O solid state relay.
Realized about 25% lower profile than conventional,
products, contributing to further miniaturization of the,
control panel G9H-205S DC24 PDF datasheet.
Push-In Plus terminal blocks are used to save wiring work,
in comparison with conventional screw terminals
G9H-205S DC24
(Wiring time is reduced by 60%* in comparison with,
traditional screw terminals.).
No screw loosening means maintenance-free application,
realizing high reliability.
Hand-free structure that holds an inserted flat-blade,
screwdriver to achieve easier wiring work for stranded wires G9H-205S DC24 PDF datasheet.
Screw terminal is also stocked to meet the screw type needs.
Mounted relay or solid-state relay has a plug-in terminal.
that is difficult to bend at the time of exchange. Main contacts: 3PST-NO.
Auxiliary contact: SPST-NC.
OFF-delay time: 30 S.
The G9SA Series Offers a Complete.
Line-up of Compact Units.
Four kinds of 45-mm wide Units are available:
A 3-pole model, a 5-pole model, and models with 3 poles,
and 2 OFF-delay poles, as well as a Two-hand Controller G9H-205S DC24 PDF datasheet.
Also available are 17.5-mm wide Expansion Units with 3,
poles and 3 OFF-delay poles.
Simple expansion connection.
OFF-delay models have 15-step OFF-delay settings.
Conforms to EN ISO13849-1 (PLe/Safety Category 4).
Both DIN track mounting and screw mounting are possible. I/O classification: Analog input.
I/O points: 4.
I/O connections: Terminal block.
Power supply voltage: 24 VDC.
I/O specification: 4 to 20 mA, 0 to 20 mA, 0 to 5 V,
1 to 5 V, 0 to 10 V, -10 to 10 V.
Analog Input/Output Units Compatible with MULTIPLE I/O TERMINAL.
Input block incorporates connectors that can be easily,
mounted or dismounted. (GT1-AD08MX, GT1-DA04MX)
8 or 4 inputs.
4 outputs.
High resolution of 1/6,000.
High conversion speed of 8 ms/8 points or 4 ms/4 points.
DIN track mounting.
Connector model Terminal Block Model. Name: Slice I/O Units; Analog I/O Units.
Specifications: Analog outputs (current).
Standards: CE, UC1, L.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be rreduced G9H-205S DC24 PDF catalog.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee G9H-205S DC24 PDF catalog.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.