Terminal (Wire connection): Screw terminal.
Classification: Microloads.
Latching lever (Test switch): No.
Rated input voltage: AC, 230V.
Global standard size, low profile slim.
I/O relay with width 6.2 mm.
Realized about 25% lower profile than conventional.
products, contributing to further miniaturization of the control panel GX-DA0271 datasheet.
Realized opening and closing ability with one pole 6 A slim shape
GX-DA0271
Micro load products for one pole 50 mA using Au-plated.
contacts for small load switching also available.
Since G2RV is a transparent case, confirming the state of,
the contact with the naked eye is possible, and easy to,
confirm abnormality on-site (installed location).
Screw terminal is also stocked to meet the screw type needs GX-DA0271 datasheet.
Mounted relay uses plug-in terminals that are difficult to,
bend when exchanging. Unit: Connector model.
I/O classification: Digital input.
Internal I/O common: PNP (- common).
I/O points: 16.
I/O connections: Molex connector.
Power supplyvoltage: 24 VDC.
I/O specification: DC/transistor.
Digital I/O Units Compatible with MULTIPLE I/O TERMINAL,
Terminal block, connector, and high-density connector,
models are available GX-DA0271 datasheet.
The circuit block of the terminal block model can be,
mounted or dismounted for ease of maintenance without,
disconnecting the wires.
DIN track mounting. Isolation: Photocoupler.
Zero cross function: --.
Indicator: Yes.
Rated output load: 2 A at 5 to 110 VDC.
Rated input voltage: 200/220 VAC.
International Standards for G3F Series,
Same Profile as MY Power Relays.
Shape-compatible with mechanical relays.
Certified by UL, CSA, and VDE (model numbers with a suffix of“-VD”).
Socket type, same size as MY Power Relays.
Operation indicator provided to confirm input.
(model numbers with “N” before the suffix). Name: Safety Controller.
Number of I/O: Safety inputs, 10; Test outputs, 6;
Safety outputs, Solid-state outputs: 16; Standard outputs, --.
Unit version: Ver.2.0.
Easy programming for complex safety control.
Stand-alone Safety Controller for small and mid-sized machinery.
Three types of CPU with different I/O size to suit the application.
Four types of Expansion I/O Units foor hard-wired diagnosis or standard signals GX-DA0271 PDF datasheet.
Clear diagnosis and monitoring via Ethernet or Serial connection.
Various kinds of safety devices directly connectable like noncontact,
switches and safety mats.
Easy design, vverification, standardization and reusage of,
safety control by unique programming software GX-DA0271 PDF datasheet.
ISO 13849-1 (PLe/Category 4), IEC61508 (SIL3) certified.