LK Automation Limited
Home >> Download >> OMRON >> Catalog Download >> OMRON K2CU-F10A-CGS PDF catalog K2CU-F10A-CGS datasheet PDF datasheet

OMRON K2CU-F10A-CGS PDF catalog K2CU-F10A-CGS datasheet PDF datasheet

Product model: K2CU-F10A-CGS
Name: Heater Element Burnout Detector
Brand: OMRON
Sort: PDF datasheet
File language: English
File size: 1.26MB
Time specification: Inverse type.
Current setting range: 20 to 65 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage K2CU-F10A-CGS PDF datasheet.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase K2CU-F10A-CGS
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K2CU-F10A-CGS PDF datasheet. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Time specification: Instantaneous type.
Current setting range: 8 to 26 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic (See note K2CU-F10A-CGS PDF datasheet. ).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Type of input: AC current input.
Output type: relay contact; 1c HH; PASS, H, L, LL: each 1a.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) some models are not equipped with depth.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table K2CU-F10A-CGS PDF catalog.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge forr monitoring the operation trend K2CU-F10A-CGS PDF catalog.
External event input can be applied to a variety of measurement and identification situations.
DeviceNet type system
Related products
OMRON
Heater Element Burnout Detector
K2CU-F20A-F
OMRON Heater Element Burnout Detector K2CU-F20A-F
Control supply voltage: 220 VAC With voltage
OMRON
Heater Element Burnout Detector
K2CU-F80A-F
OMRON Heater Element Burnout Detector K2CU-F80A-F
Control supply voltage: 220 VAC With voltage
OMRON
Heater Element Burnout Detector
K2CU Series
OMRON Heater Element Burnout Detector K2CU Series
Accurate Detection of Heater Element. Burnou
OMRON
Heater Element Burnout Detector
K2CU-F80A-FGS
OMRON Heater Element Burnout Detector K2CU-F80A-FGS
Control supply voltage: 220 VAC With voltage