Product model: K2CU-P0.5A-A
Name: Heater Element Burnout Detector
Brand: OMRON
Sort: PDF datasheet
File language: English
File size: 1.26MB
Measuring voltage: 1 to 10 V AC/DC, 3 to 30 V AC/DC, 15 to 150 V AC/DC.
Supply voltage: 100-115 VAC.
Ideal for voltage monitoring for industrial.
facilities and equipment.
Monitor for overvoltages and undervoltages simultaneously.
Separate settings and outputs supported for overvoltages and,
undervoltages K2CU-P0.5A-A PDF datasheet.
Manual resetting and automatically resetting supported by one Relay K2CU-P0.5A-A
Pre-alarm Monitoring Mode.
Two SPDT output relays, 6 A at 250 VAC (resistive load).
Process control signal (0 to 10 V) and current splitter input supported.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply. Input type: PNP input type K2CU-P0.5A-A PDF datasheet.
Event input terminal 5 points (S-TMR, HOLD, RESET) is equipped with.
External power 80mA DC12V.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
Linearity: voltage; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
Digital rotating pulse meter with high speed measurement for 50kHz.
Action determine the color, can switch the green / Red 2 kinds of color display K2CU-P0.5A-A PDF datasheet.
Measurement of 50kHz high speed pulse.
Rotary encoder and a variety of ON/OFF pulse signals, the most up to 50kHz of high-speed pulse measurementTime specification: Instantaneous type.
Current setting range: 50 to 160 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated fromm the start of operation K2CU-P0.5A-A PDF catalog.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K2CU-P0.5A-A PDF catalog. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
Related products
OMRON
Heater Element Burnout Detector
K2CU-P2A-B
OMRON Heater Element Burnout Detector K2CU-P2A-B
Control supply voltage: 110/220 VAC With vol
OMRON
Heater Element Burnout Detector
K2CU-P0.5A-B
OMRON Heater Element Burnout Detector K2CU-P0.5A-B
Control supply voltage: 110/220 VAC With vol
OMRON
Heater Element Burnout Detector
K2CU-P4A-A
OMRON Heater Element Burnout Detector K2CU-P4A-A
Control supply voltage: 100/ 200 VAC With vo
OMRON
Heater Element Burnout Detector
K2CU-P1-A
OMRON Heater Element Burnout Detector K2CU-P1-A
Control supply voltage: 100/ 200 VAC Without