LK Automation Limited
Home >> Download >> OMRON >> Catalog Download >> OMRON K3HB-CNB-A1 AC100-240 PDF catalog K3HB-CNB-A1 AC100-240 datasheet PDF datasheet

OMRON K3HB-CNB-A1 AC100-240 PDF catalog K3HB-CNB-A1 AC100-240 datasheet PDF datasheet

Product model: K3HB-CNB-A1 AC100-240
Name: Cumulative / increase / decrease pulse meter
Brand: OMRON
Sort: PDF datasheet
File language: English
File size: 1.34MB
Power supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: One relay output.
Communications output: RS-485.
Current input range: 2.00 to 22.00 A.
A high-precision Heater Element K3HB-CNB-A1 AC100-240 PDF datasheet.
Burnout Detector compatible with a,
wide-range of heater control methods K3HB-CNB-A1 AC100-240
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance K3HB-CNB-A1 AC100-240 PDF datasheet.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Input type: DC current input.
Output type: linear; current; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with K3HB-CNB-A1 AC100-240 PDF datasheet.
External supply 80mA DC12V.
Power supply voltage: AC/DC24V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
DeviceNet typeTime specification: Instantaneous type.
Current setting range: 2 to 8 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the starrt of operation K3HB-CNB-A1 AC100-240 PDF catalog.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-CNB-A1 AC100-240 PDF catalog. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
Related products
OMRON
Time interval table
K3HB-PPB-AT11 AC100-240
OMRON Time interval table K3HB-PPB-AT11 AC100-240
Input type: PNP input type. Event input term
OMRON
Time interval table
K3HB-PPB-ABCD1 AC100-240
OMRON Time interval table K3HB-PPB-ABCD1 AC100-240
Input type: PNP input type. Event input term
OMRON
Temperature Monitoring Relay
K8AB-TH12S AC100-240
OMRON Temperature Monitoring Relay K8AB-TH12S AC100-240
Size: K8AB-TH 22.5 × 90 × 100 mm. Supply vol
OMRON
Voltage and current panel meter
K3HB-XAA-L2AT11 AC100-240
OMRON Voltage and current panel meter K3HB-XAA-L2AT11 AC100-240
Type of input: AC current input. Output type