Power supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: One relay output.
Communications output: RS-485.
Current input range: 0.200 to 2.200 A.
A high-precision Heater Element K3HB-PNB-ABCD1 AC100-240 PDF datasheet.
Burnout Detector compatible with a,
wide-range of heater control methods
K3HB-PNB-ABCD1 AC100-240
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance K3HB-PNB-ABCD1 AC100-240 PDF datasheet.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Ideal for voltage monitoring for industrial.
facilities and equipment.
Monitor for overvoltages or undervoltages.
Manual resetting and automatically resetting supported by one Relay K3HB-PNB-ABCD1 AC100-240 PDF datasheet.
One SPDT output relay, 6 A at 250 VAC (resistive load).
Output relay can be switched between normally open and normally closed.
Process control signal (0 to 10 V) and current splitter input supported.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply. Input type: high speed response type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External power supply DC12V80mA.
Output type: relay contact; PASS1c; HH, H, L, LL: each 1a.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
High speed, high precision measurement, determine the color display,
Can switch the green / Red 2 kinds of display colors.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
Series of DeviceNet type.
The depth (panel below) is only short size 95mm.
UL standardTime specification: Inverse type.
Current setting range: 8 to 26 A.
Operating voltage: 400/440 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start oof operation K3HB-PNB-ABCD1 AC100-240 PDF catalog.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-PNB-ABCD1 AC100-240 PDF catalog. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.