LK Automation Limited
Home >> Download >> OMRON >> Catalog Download >> OMRON K3HB-PPB-ABCD1 AC/DC24V datasheet PDF datasheet

OMRON K3HB-PPB-ABCD1 AC/DC24V datasheet PDF datasheet

Product model: K3HB-PPB-ABCD1 AC/DC24V
Name: Time interval table
Brand: OMRON
Sort: PDF datasheet
File language: English
File size: 1.59MB
A collection of shell: the shell embedded R2 shell.
Purpose: high voltage PC (reactor) grounding system.
Static ground directional relay K2GS-B type,
Advanced ground direction relay corresponding to the diversification of ground fault.
Feeder priority cut-off function for coordinated multi segment setting K3HB-PPB-ABCD1 AC/DC24V datasheet.
Prevention of low frequency vibration with other circuit accidents,
Circuit for locking circuit and preventing effect of electric wave caused by false action,
In order to improve the reliability K3HB-PPB-ABCD1 AC/DC24V
The coordination device for the zero phase action voltage is set up,
Therefore, the influence of the residual voltage can be avoided.
Due to the built-in filter, so in the event of the occurrence of the ramp wave input can also maintain a stable role,
Because of the signal level detection, it is easy to carry out the action experiment and set up the confirmation K3HB-PPB-ABCD1 AC/DC24V datasheet. Control supply voltage: 110 VAC; With voltage fluctuation compensation.
Operating current: 16 to 40 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal K3HB-PPB-ABCD1 AC/DC24V datasheet.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out.
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with both single-phase and three-phase heaters.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage. Time specification: Inverse type.
Current setting range: 20 to 65 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start off operation K3HB-PPB-ABCD1 AC/DC24V PDF datasheet.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-PPB-ABCD1 AC/DC24V PDF datasheet. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
Related products
OMRON
Time interval table
K3HB-PNB-ABCD1 AC/DC24V
OMRON Time interval table K3HB-PNB-ABCD1 AC/DC24V
Input type: NPN/ voltage pulse input type. E
OMRON
Time interval table
K3HB-PPB-ABCD1 AC100-240
OMRON Time interval table K3HB-PPB-ABCD1 AC100-240
Input type: PNP input type. Event input term
OMRON
Load sensor, mV instrument
K3HB-VLC-BBCD1 AC/DC24V
OMRON Load sensor, mV instrument K3HB-VLC-BBCD1 AC/DC24V
Category: external supply 100mA DC10V. Input
OMRON
Rotating pulse meter
K3HB-RNB-ABCD1 AC/DC24V
OMRON Rotating pulse meter K3HB-RNB-ABCD1 AC/DC24V
Input type: NPN/ voltage pulse input type. E