LK Automation Limited
Home >> Download >> OMRON >> Catalog Download >> OMRON K3HB-XAD-L2AT11 AC/DC24 PDF catalog K3HB-XAD-L2AT11 AC/DC24 datasheet PDF datasheet

OMRON K3HB-XAD-L2AT11 AC/DC24 PDF catalog K3HB-XAD-L2AT11 AC/DC24 datasheet PDF datasheet

Product model: K3HB-XAD-L2AT11 AC/DC24
Name: Voltage and current panel meter
Brand: OMRON
Sort: PDF datasheet
File language: English
File size: 1.90MB
Supply voltage: 24 VDC.
Input type: DC voltage, DC current, or NPN input.
Output type: Judgement output, 3 transistor outputs (NPN open collector);
Data transmission output, DC current (0 to 20 mA, 4 to 20 mA).
1/32 DIN Digital Panel Meter for Downsizing.
Equipment and Control Panels.
Compact size: 48 x 24 x 82 (W x H x D) K3HB-XAD-L2AT11 AC/DC24 PDF datasheet.
Multi-input compatible: DC voltage/current, rotary pulse K3HB-XAD-L2AT11 AC/DC24
Two display colors (switchable): green/red.
Selectable outputs.
CE marking and UL/CSA approval.
Splash-proof construction (NEMA4X: equivalent to IP66). Wide Range of Nozzles for Optimal.
Ionization.
A wide range of nozzle variations.
High-frequency AC method with excellent ion balance. Power supply voltage: 100 to 240 VAC K3HB-XAD-L2AT11 AC/DC24 PDF datasheet.
Heater control method: ON/OFF control SSR control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 0.200 to 2.200 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload K3HB-XAD-L2AT11 AC/DC24 PDF datasheet.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Category: external supply 100mA DC5V type.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
Relay contact: H; PASS1c, L: each 1c.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified K3HB-XAD-L2AT11 AC/DC24 PDF catalog.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend K3HB-XAD-L2AT11 AC/DC24 PDF catalog.
External event input can be applied to a variety of measurement and identification situations.
Related products
OMRON
Time interval table
K3HB-PPB-AT11 AC/DC24V
OMRON Time interval table K3HB-PPB-AT11 AC/DC24V
Input type: PNP input type. Event input term
OMRON
Temperature panel
K3HB-HTA-L1AT11 AC/DC24
OMRON Temperature panel K3HB-HTA-L1AT11 AC/DC24
Type of input: platinum resistance / thermoco
OMRON
Load sensor, mV instrument
K3HB-VLC-L2ET11 AC/DC24
OMRON Load sensor, mV instrument K3HB-VLC-L2ET11 AC/DC24
Category: external supply 100mA DC5V type. I