Time specification: Instantaneous type.
Current setting range: 2 to 8 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage K6EL-500 datasheet.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase
K6EL-500
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K6EL-500 datasheet. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Time specification: Inverse type.
Current setting range: 8 to 26 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three K6EL-500 datasheet.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Product: Standard Nozzle.
Wide Range of Nozzles for Optimal.
Ionization.
A wide range of nozzle variations.
High-frequency AC method with excellent ion balance. Category: external supply 100mA DC10V.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
Linear: current; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
Too support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified K6EL-500 PDF datasheet.
Action determine the color, can switch the green / Red 2 kinds of color display K6EL-500 PDF datasheet.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to