Product model: K8AK-VW3 24VAC/DC
Name: Single-phase Overvoltage/Undervoltage Relay
Brand: OMRON
Sort: PDF datasheet
File language: English
File size: 0.97MB
Type of input: platinum resistance / thermocouple input.
Event input terminal 4 points (TIMING, S-TIM, HOLD, RESET) is equipped with.
BCD+ transistor: -- NPN open collector (5 bit output +HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24.
Temperature indicator and measurement of various processes K8AK-VW3 24VAC/DC datasheet.
Action determine the color, can switch the green / Red 2 kinds of color display K8AK-VW3 24VAC/DC
High speed sampling of 50 /s (20ms).
0.01 degree: platinum temperature resistance body Pt100 high resolution.
Thermocouple sensor (full range) to support the resolution of 0.1.
By 2 points can be easily set the temperatureStandard function model: detection of under voltage.
Appearance: ADR shell K8AK-VW3 24VAC/DC datasheet.
Open circuit: voltage, no voltage, DC circuit breaker.
Rated voltage: AC110V.
Rated frequency: 50/60Hz.
Voltage adjustment range: 60-65-70-75-80-85-90V (7 shunt).
Time hopping: timing; -0.2-0.4-0.6-0.8-1.0
-1.2-1.4-1.6-1.8-2.0s (11 shunt).
Control power supply: No, and input common; there, DC operation.
Rating consumption VA: No, 6VA (input side);
Have, 2VA (input side) 10W (control power supply side) K8AK-VW3 24VAC/DC datasheet.
Control: 1C, 1A AC110V 7.5Acos output with =0.4
(max 250V 825VA AC);
24V 5A L/R=7ms DC (max 125V 50W when DC).
Display: start display (LED display),
Action display (trip) manual reset.
Automatic experiment: -.
Quality: about 2kg.
External: Mount Searl N1.5.
Static voltage relay.
K2VR-S/K2VA-S type, high action reliability disk with static type UVR/OVR.
Accurate work through high reliability semiconductor circuits.
Type K2VU-S1 is the output contact, but will be closed when the voltage is not enough,
Therefore, the locking time sequence circuit of the circuit breaker is not required.
Within the hidden from the start to the 2S timer, can easily adjust the time.
The control power of the relay is not needed, which avoids the trouble of wiring.
Input type: PNP input type.
Event input terminal 5 points (S-TMR, HOLD, RESET) is equipped with.
External power 80mA DC12V.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
Linear: current; NPN open collector (HH, H, PASS, L, LL) K8AK-VW3 24VAC/DC PDF datasheet.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
Digital rotating pulse meter with high speed measurement for 50kHz.
Action determine the color, can switch the green / Red 2 kinds of color displlay K8AK-VW3 24VAC/DC PDF datasheet.
Measurement of 50kHz high speed pulse.
Rotary encoder and a variety of ON/OFF pulse signals, the most up to 50kHz of high-speed pulse measurement
Related products
OMRON
Single-phase Overcurrent/Undercurrent Relay
K8AK-AW1 24VAC/DC
OMRON Single-phase Overcurrent/Undercurrent Relay K8AK-AW1 24VAC/DC
Setting range: 2 to 20 mA AC/DC, 10 to 100 mA
OMRON
Single-phase Overcurrent/Undercurrent Relay
K8AK-AW2 24VAC/DC
OMRON Single-phase Overcurrent/Undercurrent Relay K8AK-AW2 24VAC/DC
Setting range: 0.1 to 1 A AC/DC, 0.5 to 5 A A
OMRON
Single-phase Current Relay
K8AK-AS1 24VAC/DC
OMRON Single-phase Current Relay K8AK-AS1 24VAC/DC
Setting range: 2 to 20 mA AC/DC, 10 to 100 mA
OMRON
Conductive Level Controller
K8AK-LS 24VAC/DC
OMRON Conductive Level Controller K8AK-LS 24VAC/DC
Power supply voltage: 24 VAC/DC. Ideal for L