Built in OMRON''s original new under voltage detection feature small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity S8AS Series PDF datasheet.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products
S8AS Series
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminals)
Support finger touch protection to prevent electric shock.
DIN guide rail simple installation.
Safety standards: CSA, C22 S8AS Series PDF datasheet. 2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer.)
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
Independent type, the function of the built-in controller is not RS-232C, the maximum 256 points.Power ratings: 180 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC)*1 S8AS Series PDF datasheet.
Output voltage: 24 V.
Output current: 7.5 A.
Alarm output *2: Sourcing.
UL Class 2 Output standards: --.
Model number(screw terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that.
conform to UL Class 2 Output standards.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1).
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.) Contribute to build high reliable systems.
Compact and Cost-effective solution.
for Back-up applications.
Easy setup for system reliability.
requirement.
Redundancy operating LED for the status confirmation.
A signal output for failure detection of power supplies.
By adjusting the power ssupply voltage to light up Balance LED,
the lifetime of power supplies will be more than twice S8AS Series PDF catalog.
Wide range input.
DC5-30V (S8VK-R10), DC10-60V (S8VK-R20).
Wide operation temperature range: -40 to 70 °C.
Safety standards::
UL508/60950-1, CSA C22 S8AS Series PDF catalog. 2 No. 107.1/60950-1.
EN50178, EN60950-1 Lloyd''s standards *2.
EMS: EN61000-6-2.
EMI: EN61000-6-3.
Six years warranty *3.