LK Automation Limited
Home >> Download >> OMRON >> Catalog Download >> OMRON S8EX-BP05048L datasheet PDF datasheet

OMRON S8EX-BP05048L datasheet PDF datasheet

Product model: S8EX-BP05048L
Name: Switch Mode Power Supply
Brand: OMRON
Sort: PDF datasheet
File language: English
File size: 4.74MB
Control power supply voltage: 100/110 VDC.
Input: DC, Input voltage range, 10 to 300 V.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL) S8EX-BP05048L datasheet.
Detect three-phase AC current for under and/or overcur,
rent using current converter S8EX-BP05048L
Available in 7 supply voltage configurations.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verse current detection.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F) S8EX-BP05048L datasheet.
LED operation indicator.
UL/CSA approval (SDV-F@). Configuration: Covered Power Supplies.
Input voltage: 100 to 240 VAC (free) (80 to 370 VDC *).
S8JX-G15005@@:Switchable between 100 to 120 VAC and 200 to 240 VAC.
(DC power cannot be input.).
Power ratings: 50 W.
Output voltage: 48 V.
Output current: 1.1 A.
Built-in fan: No.
Easy-to-use, Widely range from 15 W to 600 W (Output Voltage: 5 V to 48 V) S8EX-BP05048L datasheet.
Easy Mounting: Front-mounted type, DIN rail-mounted type are available.
Screw-mount at the top. (except 300-/600-W models).
Safety standards: UL 508/60950-1, cUL CSA C22.2 No. 107.1,
cUR CSA C22.2 No. 60950-1.
EN 50178 (= VDE 0160) Over voltage.
category III.
EN 60950-1 (= VDE 0805 Teil 1).
EMC: Conforms to EN 61204-3.
(EMI:EN55011 ClassA).
Input conditions: The input voltage range of 15-W, 35-W,
50-W, 100-W, and 150-W models has,
been increased to 80 to 370 VDC (EC Directives and safety standards do not apply.).Power ratings: 480 W.
Input voltage: 100 to 240 VAC.
Output voltage: 24 V.
Output current: 20 A Peak current 30 A (200 VAC).
Alarm output *2: Sinking/sourcing.
UL Class 2 Output standards: --.
Model number(screw terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that.
conform to UL Class 2 Output standards. S8EX-BP05048L PDF datasheet.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 ((= VDE 0805 Teil 1) S8EX-BP05048L PDF datasheet.
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.)
Related products
OMRON
Switch Mode Power Supply
S8EX-BP24024
OMRON Switch Mode Power Supply S8EX-BP24024
Power ratings: 240 W. Output voltage: 24 V.
OMRON
Switch Mode Power Supply
S8EX-BP24048L
OMRON Switch Mode Power Supply S8EX-BP24048L
Power ratings: 240 W. Output voltage: 48 V.
OMRON
Switch Mode Power Supply
S8EX-BP15012LC
OMRON Switch Mode Power Supply S8EX-BP15012LC
Power ratings: 150 W. Output voltage: 12 V.
OMRON
Switch Mode Power Supply
S8EX-BP05005LC
OMRON Switch Mode Power Supply S8EX-BP05005LC
Power ratings: 50 W. Output voltage: 5 V. O