Control power supply voltage: 200/220 VAC.
Input: DC or AC (selectable); input voltage range: 10 to 300 V: Operating mode,
ON-delay; OFF-delay; Startup lock.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V SC-P2 PDF catalog.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL)
SC-P2
Detect three-phase AC current for under and/or overcur,
rent using current converter.
Available in 7 supply voltage configurations.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verse current detection SC-P2 PDF catalog.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F).
LED operation indicator.
UL/CSA approval (SDV-F@). Appearance: insert type.
Control supply voltage: AC200/220/240V.
Action elements: overload detection.
Action characteristic: anti time limit action type.
Especially suitable for single phase motor over current protection.
Can be used for motor overload protection, common single-phase circuit of the AC current detection SC-P2 PDF catalog.
A variety of models, such as anti time limit characteristics, lock time, instantaneous action, etc., are provided,
The product is rich in variety, and can be effectively protected, detected and controlled according to the actual situation OMRON Limit Switch Connectors PDF catalog.
When the current is large, the input resistance of the CT or the relay part is not needed, and the use is simple OMRON Limit Switch Connectors PDF catalog.
Because it is a plug-in, installation, disassembly, wiring and other operations are very simple. Configuration: Covered Power Supplies.
Input voltage: 100 to 120 VAC 200 to 240 VAC (Switchable).
Power ratings: 300 W.
Output voltage: 12 V.
Output current: 27 A OMRON Limit Switch Connectors PDF catalog.
Built-in fan: Yes.
Easy-to-use, Widely range from 15 W to 600 W (Output Voltage: 5 V to 48 V).
Easy Mounting: Front-mounted type, DIN rail-mounted type are available.
Screw-mount at the top. (except 300-/600-W models).
Safety standards: UL 5508/60950-1, cUL CSA C22 SC-P2 PDF datasheet. 2 No. 107.1,
cUR CSA C22.2 No. 60950-1.
EN 50178 (= VDE 0160) Over voltage.
category III.
EN 60950-1 (= VDE 0805 Teil 1).
EMC: Conforms to EN 61204-3.
(EMI:EN55011 ClassA).
Input conditions: The inpuut voltage range of 15-W, 35-W,
50-W, 100-W, and 150-W models has,
been increased to 80 to 370 VDC (EC Directives and safety standards do not apply SC-P2 PDF catalog. ).