Size: M18, Non-shielded.
Sensing distance: 16.0 mm.
Connection: M12 connector.
Body material: Brass.
Thread length (overall length): 39 (53).
Output configuration: PNP.
Operation mode NC.
Safe Mounting with Greater.
Sensing Distance.
Ensures a sensing distance approximately 1.5 to 2,
times larger than that of any conventional OMRON Sensor E3FA Series/E3RA Series/E3FB Series PDF catalog .
Problems such as the collision of workpieces are eliminated
E3FA Series/E3RA Series/E3FB Series
Full range of standard sizes (M8, M12, M18 and,
M30; both long and short barrels).
Modular construction simplifies customization. Size: 48 * 48mm, terminal type.
Type: control output 2 point type (power AC/DC24V).
Shell color: black.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver) E3FA Series/E3RA Series/E3FB Series PDF catalog .
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event input points: -.
Transfer output: -.
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved E3FA Series/E3RA Series/E3FB Series PDF catalog .
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors OMRON E3FA Series/E3RA Series/E3FB Series PDF datasheet.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV OMRON E3FA Series/E3RA Series/E3FB Series PDF datasheet.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can perform flexible contact output OMRON E3FA Series/E3RA Series/E3FB Series PDF datasheet.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Size: 48 x 48mm.
Control output 1: voltage.
Auxiliary (alarm) output: 3.
Transfer output: -.
Event input: 2.
Communication: RS-485.
Disconnection detection: 1.
Power supply voltage: AC100 ~ 240V.
The white PV (current value) with excellent visibility shows the segment to make the confirmation work more easily.
Eye-catching white + industry''s largest display size
The black and white display and the industry''s largest display size to achieve excellent visibility.
No matter from which angle or in the natural lighting environment, the dark scene,
Can quickly and accurately confirm the current value E3FA Series/E3RA Series/E3FB Series datasheet.
Displays the current value (PV/ white), the target value (SV/ green) and the progress of tthe program (PRG, SEG/ yellow) E3FA Series/E3RA Series/E3FB Series PDF catalog .
Can be viewed at the same time, there is no need to switch the display, so as to improve the efficiency of operations.