Analog output channel number: 8CH.
accuracy
Ambient temperature of 25 plus or minus 5 degrees C: plus or minus 0.1%.
Ambient temperature 0 ~ 55 degrees C:-.
Temperature coefficient: positive and negative 50ppm/.
Conversion speed: 1ms/CH.
Insulation between channels: isolation transformer insulation.
Output short circuit protection: have MITSUBISHI Programmable logic controller CPU PDF datasheet.
External power supply: -
R120ENCPU
External wiring connection mode: 40 pin connector.
Voltage output
Digital input value: 32000 ~ 32000.
Analog output voltage: DC - 10 - 10V.
Current output
Digital input value: 0 ~ 32000.
Analog output current: DC0 ~ 20mA.
High speed output flow simulation waveform.
The analog output module has the function of registering arbitrary waveform data to the module, and continuously executing the analog output according to the set conversion cycle MITSUBISHI Programmable logic controller CPU PDF datasheet.
Execute the analog quantity (torque) control of stamping machine and injection molding machine, can automatically output the control waveform,
Through the process of high speed, smooth control. In addition, only prior to the waveform data are registered in the module,
Can easily control the analog waveform, so the production line control, such as repetitive control,
Without using a special program to create the waveform, can reduce the programming time MITSUBISHI Programmable logic controller CPU PDF datasheet R120ENCPU PDF datasheet.
Easy to use parameters to set the conversion operation and scaling, no need to create a dedicated program.
Therefore, it is helpful to reduce the development cost of the program and to reduce the program capacity R120ENCPU PDF datasheet. Output points: 64 points.
Output form: Transistor (source) output.
Rated open and close voltage, current: -.
Rated load voltage: DC12 ~ 24V.
Max load current: 0.1A/ point.
Response time: 1ms.
Common way: 32 point / public end R120ENCPU PDF datasheet.
Protection function (overload, overheat).
External wiring connection: 40 pin connector two.
Output module with mechanical relay contact mechanism,
Including the load voltage range of the relay and can be used for the output of the DC12~24V load transistor output type.
According to the load voltage, the output points of different, choose the most suitable user needs of the module R120ENCPU PDF catalog.
Preventive maintenance based on the life of relay contact.
Relay output module can accumulate the number of OON of each output point MITSUBISHI Programmable logic controller CPU PDF datasheet.
Through the understanding of the relay contacts of the number of times, according to the relay life of preventive maintenance.