Number of elements: 3.
Isolation method: Phototriac coupler.
Rated powersupply voltage: 100 to 240 VAC.
Input method: No-voltage input (open and short circuited input).
Applicable monitor capacity (AC3): 3.7 kW (17.4 A), 200 to 220 VAC.
Monitor output: AC switching output.
New Models with AC Power Supply Input and,
Monitor Output Equivalent to Non-contact,
SPST-NO Join the G3J-T Series,
Limiting the starting current saves energy GT1-ROS16 PDF catalog
GT1-ROS16
Certified for UL and CSA.
Mounts with screws or to DIN Track.
Compact design with heat sinks (3.7-kW models: 100 × 100 ×130 mm (W × H × D)).
Built-in snubber circuit and thyristor.
Built-in operation indicator. Safety outputs *3: Instantaneous, 3(Semiconductor);
OFF-delayed*2, 2 (Semiconductor) GT1-ROS16 PDF catalog .
Auxiliary outputs *4: 2(Semiconductor).
Logical AND connection: Inputs, 1(Semiconductor); Outputs, 1(Semiconductor).
No. of input channels: 1 or 2 channels.
Max. OFF-delay time *1: 15 s.
Rated voltage: 24 VDC.
Terminal block type: Screw terminals.
Logical AND Function Adds Flexibility to I/O Expansion.
Facilitates partial or complete control system setup GT1-ROS16 PDF catalog .
Solid-state outputs (excluding Expansion Units).
Detailed LED indications enable easy diagnosis.
TÜV SÜD certification for compliance,
with IEC/EN61508 (SIL3), EN ISO13849-1 (PLe/Safety Category 4).
Approved by UL and CSA.
New unit joins the Series with the following two additional features:
-OFF-delay time of up to 150 seconds can be set OMRON GT1-ROS16 PDF datasheet.
-Two logical AND connection inputs OMRON GT1-ROS16 PDF datasheet. Name: CompoNet Communication Unit.
Specifications: Up to 64 Slice I/O,
Units can be connected.
(Inputs: 32 bytes maximum,
Output: 32 bytes maximum).
Standards: CE, UC1, L.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet OMRON GT1-ROS16 PDF datasheet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Type: output module.
Insulation: photo coupler.
Zero crossing function: No.
Action ddisplay lamp GT1-ROS16 datasheet.
Output rated voltage: DC48 1.5A ~ 200V.
Input rated voltage: DC5 ~ 24V.
Logic circuit and load interface.
I/O solid state relay.
With the input module (AC, DC), the output module (AC, DC).
Product series, tthe color of each module to distinguish GT1-ROS16 PDF catalog .
You can confirm the action of SSR by using the action display light.
Between input and output voltage 4000V.