Home >> Download >> OMRON >> Catalog Download >> Single-phase Voltage Relay K8AB-VS2 AC200/230V datasheet PDF catalog OMRON K8AB-VS2 AC200/230V PDF datasheet

Single-phase Voltage Relay K8AB-VS2 AC200/230V datasheet PDF catalog OMRON K8AB-VS2 AC200/230V PDF datasheet

Product model: K8AB-VS2 AC200/230V
Name: Single-phase Voltage Relay
Brand: OMRON
Sort: PDF datasheet
File language: English
File size: 0.83MB
Input type: PNP input type.
Event input terminal 5 points (HOLD, RESET) equipped with.
External power supply DC12V80mA.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
Communication: RS-232C; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V K8AB-VS2 AC200/230V PDF catalog .
Measurement of 2 points through the speed, time, or cycle of the digital time interval table K8AB-VS2 AC200/230V
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of wide range of pulse interval time.
Measuring, calculating and displaying the pulse interval between 2 points.
Pulse interval measurement range, maximum measurablePower supply voltage: 100 to 240 VAC K8AB-VS2 AC200/230V PDF catalog .
Heater control method: ON/OFF control SSR control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 0.200 to 2.200 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload K8AB-VS2 AC200/230V PDF catalog .
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement OMRON K8AB-VS2 AC200/230V PDF datasheet.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads OMRON K8AB-VS2 AC200/230V PDF datasheet.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Time specification: Instantaneous type.
Current setting range: 8 to 26 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual OMRON K8AB-VS2 AC200/230V PDF datasheet.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
iis indicated from the start of operation K8AB-VS2 AC200/230V datasheet.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequeency, basic,
frequency, and load conditions K8AB-VS2 AC200/230V PDF catalog . Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
Related products
OMRON
Single-phase Voltage Relay
K8AB-VW2 AC200/230V
OMRON Single-phase Voltage Relay K8AB-VW2 AC200/230V
Measuring voltage: 1 to 10 V AC/DC, 3 to 30 V
OMRON
Single-phase Voltage Relay
K8AB-VS1 AC200/230V
OMRON Single-phase Voltage Relay K8AB-VS1 AC200/230V
Measuring voltage: 6 to 60 mV AC/DC, 10 to 10
OMRON
Single-phase Voltage Relay
K8AB-VS2 AC/DC24V
OMRON Single-phase Voltage Relay K8AB-VS2 AC/DC24V
Measuring voltage: 1 to 10 V AC/DC, 3 to 30 V
OMRON
Single-phase Voltage Relay
K8AB-VS2 AC200/230V
OMRON Single-phase Voltage Relay K8AB-VS2 AC200/230V
Measuring voltage: 1 to 10 V AC/DC, 3 to 30 V