Isolation: Phototriac coupler.
Zero cross function: No.
Indicator: Yes.
Rated output load: 3 A at 100 to 240 VAC (See note 1.).
Rated input voltage: 24 VDC.
International Standards for G3F Series,
Same Profile as MY Power Relays.
Shape-compatible with mechanical relays.
Certified by UL, CSA, and VDE (model numbers with a suffix of“-VD”) G2RV-SR500 AC100 PDF datasheet .
Socket type, same size as MY Power Relays
G2RV-SR500 AC100
Operation indicator provided to confirm input.
(model numbers with “N” before the suffix). Safety instantaneous output: 2 (Semiconductor).
Safety slow-speed/stopping detection output: 2 (Semiconductor).
Auxiliary output: 4(Semiconductor).
Maximum set threshold: 10 Hz.
voltage Rated: 24 VDC.
Terminal block type: Screw terminals G2RV-SR500 AC100 PDF datasheet .
Low-speed Monitoring Function Ensures.
Safety for Maintenance Work.
Motor rotation speed detected by Proximity Sensor.
Monitors and confirms that speed does not exceed the preset level.
Includes an Enabling Switch input for maintenance work.
Detailed LED indications enable easy fault diagnosis.
Safety Category 3 (EN954-1), PLd(ISO13849-1),
SIL 3 (IEC/EN 62061) certified G2RV-SR500 AC100 PDF datasheet . Standard certification: No.
Action indicator: there.
Applicable load of output: DC5 2A ~ 110V.
Input rated voltage: AC200/220V.
Insulation: photo coupler.
Zero trigger function: No.
And the MY type of the same shape of the G3F series of new international standard certification (-VD type) OMRON G2RV-SR500 AC100 PDF catalog.
Achieved UL, CSA, EN (VDE certification) standard certification OMRON G2RV-SR500 AC100 PDF catalog. (type -VD)
Socket terminal type of same size with MY (2 pole type).
A model with an action indicator to check the status of the input. Standard certification: No.
Action indicator: No.
Applicable load of output: AC100 3A ~ 240V.
Input rated voltage: DC5V.
Insulation mode: three end two-way photoelectric switch OMRON G2RV-SR500 AC100 PDF catalog.
Zero crossing trigger function.
And the MY type of the same shape of the G3F series of new international standard certification (-VD type).
Achieved UL, CSA, EN (VDE certification) standard certification. (type -VD)
Socket terminal type of same size with MY (2 pole type).
A model with an action indicator to check the status of the input. Isolation: Photocoupler.
Zero cross function: Yes.
Indicator: Yes(Yellow).
Applicable output load (See note 1.): 90 A at 24 to 240 VAC(See note 2.).
Rated input voltage: 100 to 120 VAC.
Wide Lineup of General-purpose Solid State.
Relays with Applicable Loads of 5 to 90 A.
AC Output Relays with 75-A and 90-A output currents have been,
added to the G3NA Series.
Alll models feature the same compact dimensions to provide a,
uniform mounting pitch G2RV-SR500 AC100 datasheet.
Built-in varistor effectively absorbs external surges.
(except G3NA-D210B).
Operation indicator enables monitoring operation.
Prrotective cover for greater safety G2RV-SR500 AC100 PDF datasheet .
Standard models certified by UL and CSA and -UTU models by TÜV.
(except G3NA-410B, G3NA-420B, and G3NA-440B(-2)).