Output points: 16 points.
Rated output voltage: DC24V/AC240V.
Rated open and close current: 2A/1 point.
Common way: 16 point / public end.
Input / output occupied points: 16 points (I/O distribution: output 16 points).
External wiring connection: 18 point terminal.
The switch input and output module is a device which can collect the input / output of the switch signal,
Digital I/O modules are often called L60RD8-CM PDF datasheet
L60RD8-CM
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can also be carried out through the RS-485 bus communication,
Remote control switch.
Communication protocol is a standard Modbus protocol or custom protocol L60RD8-CM PDF datasheet . Control axis: maximum 16 axes.
Operation cycle: 0.88ms, 1.77ms.
Interpolation function: linear interpolation (maximum 4 axis), 2 axis arc interpolation.
Color signal: 4 points.
Color detecting set: 16 set.
Only need to use the PLC program can easily achieve synchronous control, cam control, speed and torque (push pressure control) and other advanced motion control.
Equipped with standard synchronous encoder and color detection function necessary function L60RD8-CM PDF datasheet .
Can be no procedures for setting. Strong support for MELSOFT.
Can fully apply LD77MH of the old program.
Let motion control more simple. "Universal output function: source type MITSUBISHI L60RD8-CM PDF catalog.
Program capacity: 260K step.
Basic operations processing speed: 9.5ns.
Communication interface: USB/Ethernet (built-in CC-Link function) MITSUBISHI L60RD8-CM PDF catalog.
Program capacity: 20K step.
Control mode: stored procedure repeated operation.
Input / output points: 4096 points.
End cap.
High precision PWM control of the highest 200kHz.
In the PWM output mode, by setting the ON time and cycle time,
The duty cycle can be changed, and the minimum cycle time is 5 s MITSUBISHI L60RD8-CM PDF catalog.
In addition to lighting dimming control, simple motor control and heater control,
Can also be used to require high resolution detection equipment, such as a wide range of oscillators.
CPU built-in functions can be easily set through programming tools.
The built-in I/O function settings can be easily carried out through the parameters of the programminng tool L60RD8-CM datasheet.
5 s units can be used for high precision workpiece measurement in pulse measurement mode,
Can be used with a minimum of 5 s units of the input signal of the ON/OFF time (the shortest 200 s) for high precision measurrement L60RD8-CM PDF datasheet .
For example, after measuring the ON time of the sensor input,