Input type: DC current input.
Output type: relay contact; 1c HH; PASS, H, L, LL: each 1a.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) some models are not equipped with depth K8AB-PA1 PDF datasheet .
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table
K8AB-PA1
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
DeviceNet type systemControl supply voltage: 100 VAC; With voltage fluctuation compensation K8AB-PA1 PDF datasheet .
Operating current: 4 to 10 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out K8AB-PA1 PDF datasheet .
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with both single-phase and three-phase heaters.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage OMRON K8AB-PA1 PDF catalog. Power supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control OMRON K8AB-PA1 PDF catalog.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: One relay output.
Communications output: RS-485.
Current input range: 20.0 to 200.0 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods OMRON K8AB-PA1 PDF catalog.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase coontrol, and cyclic control K8AB-PA1 datasheet.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurreent relay or for motor or lamp loads K8AB-PA1 PDF datasheet .
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).