Three-phase Phase-sequence Phase-loss.
Relay Using Voltage Detection Method.
Fixed phase Asymmetry monitoring.
Prevents reverse motor rotation due to incorrect wiring.
Distinguishes between positive phases, reversed phases, and phase,
loss when power is turned ON.
Voltage detection method enables application for any load current K3HB-PPB-A1 AC100-240 PDF datasheet .
One SPDT output relay, 6 A at 250 VAC (resistive load)
K3HB-PPB-A1 AC100-240
Output status can be monitored using LED indicator. Time specification: Instantaneous type.
Current setting range: 50 to 160 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase) K3HB-PPB-A1 AC100-240 PDF datasheet .
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction K3HB-PPB-A1 AC100-240 PDF datasheet .
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements OMRON K3HB-PPB-A1 AC100-240 PDF catalog. It is recommended to test operation,
before using the K2CM. Category: ontology; power monitoring OMRON K3HB-PPB-A1 AC100-240 PDF catalog.
Application circuit: single phase 2 wire; single phase 3 wire; three-phase 3 wire.
Supply voltage: AC100 ~ 240V (50/60Hz).
Output function: open collector output; cumulative output pulse output; alarm output.
Communication specifications: RS-485.
Memory card function: No.
Simple monitoring of the use of electricity to support energy saving countermeasures OMRON K3HB-PPB-A1 AC100-240 PDF catalog.
On behalf of the use of the mechanical equipment, the measurement of the initial vooltage, current,
Cumulative quantity, invalid power, power factor, frequency K3HB-PPB-A1 AC100-240 datasheet.
To achieve a simple record with a memory card. (with memory card function model)
The measurement data can be stored in the main body, and the centralized monitoring and management can be carried out in the communication network K3HB-PPB-A1 AC100-240 PDF datasheet .
Wide 45mm miniaturization, simple set to the DIN guide.