Inverter input power: 3 phase / single phase AC200V.
Weight: 1.3KG.
Standard applicable line diameter: 2 square mm or more.
Used to suppress harmonic currents generated by a transducer.
The effect of harmonic current suppression is better than that of AC reactor,
And it can be used with AC reactor. Born to drive machines OMRON 3G3AX-MX2-DRT-E Communications Manual.
Positioning functionality.
Fieldbus communications with optional unit,
EtherCAT, CompoNet and DeviceNet,
Drive Programming
3G3AX-MX2-DRT-E
Current vector Control.
High Starting torque: 200% at 0.5 Hz.
Safety function * EN ISO 13849-1:2008 (Cat.3/PLd),
IEC 60204-1 Stop Category 0,
Speed range up to 580 Hz.
When optional DeviceNet communication unit or CompoNet communication unit is,
mounted onto the MX2-series V1 type, the inverter will not conform to the safety,
standards OMRON 3G3AX-MX2-DRT-E Communications Manual. Specification: medium capacity type.
Impact resistance: 400W.
Resistance to impact resistance: 50.
The use of resistance to consume the motor regenerative energy, thereby reducing the time to slow down.
Alarm output terminal of braking resistor.
When the temperature relay of the braking resistor is activated, a circuit for cutting the main power supply of the frequency converter is formed OMRON 3G3AX-MX2-DRT-E Communications Manual. Inverter input power: 3 phase / single phase AC200V.
Weight: 3.6KG.
Standard applicable line diameter: 8 square mm or more.
Used to suppress harmonic currents generated by a transducer.
The effect of harmonic current suppression is better than that of AC reactor,
And it can be used with AC reactor. Function name: 3 phase 200V.
Power: 0.2KW.
Rated output voltage: 3 phase, 200 ~ 240V (the output voltage can not exceed the input voltage).
Built in brake unit (brake resistance needs to be matched).
Weight: 1.0KG.
Dimension (w * h) 128mm *:68.
Outline dimension (deep):109mm.
Mechanical automation concept.
Positioning function.
The use of options.
(EtherCAT, CompoNet and DeviceNet) to realize the field bus communication.
Driver programming function.
Current vector control.
High starting torque: 0.5Hz up to 200%.
Safety features, in compliance with ISO13849-1:2008 EN (Cat.3/PLd) and IEC60204-1 stop level 0 standard.
Frequency output up to 580H. Specification: three phase 200V.
Power: 0.2KW.
Maximum output voltage: three phase input voltage.
Rated voltage, frequency: three-phase power supply 200 ~ 50/60Hz, 240V.
Cooling way: natural wind cooling.
Weight: 1.1kg.
Open loop vector control mode of low speed and high torque, rich control function and convenient distribution management network function,
Set in one of the inverter --3G3MZ.
3G3MZ series inverter for the application of frequency control and development.
Humanized design and advanced management technology, as well as OMRON a simple style of modeling, feature rich style,
Combined with the latest technical needs of users, so that it has a noble lineage and the most close to the market elements 3G3AX-MX2-DRT-E Manual.
Covers the special features of the fan pumpp class, open loop vector function,
Built in noise filter and a variety of network bus,
3G3MZ will be your most economical and the most perfect choice 3G3AX-MX2-DRT-E Manual.