LK Automation Limited
Home >> Download >> Proface >> Manual Download >> AGP3750-T1-D24-M Manual Proface Vision Sensor AGP3750-T1-D24-M User's Manual

AGP3750-T1-D24-M Manual Proface Vision Sensor AGP3750-T1-D24-M User's Manual

Product model: AGP3750-T1-D24-M
Name: Vision Sensor
Brand: Proface
Sort: User's Manual
File language: English
File size: 4.84MB
Size: 3.8 inches.
Display type: monochrome (amber / red) LCD.
Resolution: 320 x 240 pixels (QVGA).
Display color: monochrome (8 gray level).
Power supply: DC24V.
Interface: USB (host), RS-232C, RS-422/485.
Backlight: amber / red LED (users can not change their own. Must be replaced by the manufacturer Proface Vision Sensor User's Manual. ).
Brightness adjustment: 16 level adjustment can be carried out by touch panel AGP3750-T1-D24-M
According to ID number of easy access to the operation log, through the analysis of the operation to improve production efficiency.
Use ID based on the number of authorized mode of operation, can be recorded when, who performed the operation.
Using this data, you can analyze the causes of all the faults that have occurred Proface Vision Sensor User's Manual.
You can easily and intuitively set the address by dragging and dropping the mouse.
In addition, click on the use of the address can be displayed on the screen number and part number.
Click the part number to jump to the screen using the widget.
The same software supports all 3000 series of Pro-face man-machine interface.
From the screen to create the programming, the functions are simple and easy to use Proface Vision Sensor User's Manual.
Learn a software, master all the skills.
Support efficient image creation.
ID management and operation log reduces downtime.
Improve the operation mode, reduce the cost and workload.
Analysis of failure causes according to the operation log AGP3750-T1-D24-M User's Manual.
Check register status on historical trend chart.
Drag and drop functionality makes the software interface easier to operate AGP3750-T1-D24-M User's Manual.
A variety of components to provide a variety of components, easy to create a beautiful picture.
In addition, there are a variety of 256 color components can be used.
Using the alarm log to quickly check and display the alarm message and register value, it is easier to find the cause of the fault AGP3750-T1-D24-M User's Manual.
Register value will be recorded when the alarm is issued.
Therefore, the state of the register and its value can be obtained while acquiring the alarm message.
A comparison of the data is helpful to find the cause of the fault.
These sample parts" can be used directly, and the design time is greatly reduced. "Specifications: DC24/H (handheld) class models.
Emergency stop switch: gray / key switch.
Display type: STN pseudo color LCD.
Display size: 5.7 inches.
Resolution: 320 x 240 pixels (QVGA).
Display color: 4096 color.
Backlight: white LED (back light lamp replacement: return to repair).
Brightness adjustment: 16 level adjustment can be carried out by touch panel.
Touch panel type: resistance type (analog).
Providing operation and maintenance instructions through video mode, which can save maintenance cost.
The operation and maintenance instructions provided by the video mode can make any operator easy to master the operation method.
Easily upgrade.
GP/ST series supports GP series of all models of the screen data, including the first generation of the GP10 series.
GP product family to maintain the size of the opening of the panel compatibility, to facilitate easy replacement.
Rich sample images can reduce programming time.
Pro-face provides a large number of sample images and 3D parts,
So you can easily create a beautiful and intuitive picture, in order to save editing time. Data transmission using USB memory.
In the production site using USB memory can be easily transferred to the production line change and change the screen data.
Safety control function can minimize the problem of production site
Password management functions can be based on each operator or administrator password to enter the set level can be operated by the screen,
According to the function of the operator to set the password to enter the level.
In order to strengthen the management, the operator must enter the ID and the password to operate the equipment.
Error visualization.
The controller is directly connected to the GP, and the key error information of the controller can be displayed on the GP by using the sample unit.
No need to open the control panel, through the PLC to monitor the GP program.
Through the data through the GP function, you can easily debug the ladder program and adjust the data due to changes in the production line by GP easily.
Use USB memory or CF card backup monthly and daily
Recording function using USB memory or CF card can easily improve the efficiency of daily and monthly.
The use of CSV data conversion function can be modified on the PLC GP settings.
Simulated running status on PC.
Use PC simulation function, do not need to transfer the picture to GP,
You can check all the functions of GP on the PC - including the screen operation, D script, logical script.
Can improve the efficiency of the 5 functions.
Using EX GP-Pro can easily create a clear picture and save the creation time.
Screen and logic programming software EX GP-Pro interface is very friendly,
The drag and drop feature makes the software interface easy to operate.
EX GP-Pro powerful features, such as 3D simulation components, image fonts and simulation functions,
Eveen beginners can easily and quickly grasp how to create a picture AGP3750-T1-D24-M Manual.
Remote operation and monitoring in the Office
In the office or other remote side can monitor the production site of the GP screen.
Without picturee editing or programming, you can achieve real-time management and monitoring, and now, you can also provide more efficient remote maintenance control Proface Vision Sensor User's Manual.
Related products