Name: CS1D Expansion Backplane.
Specifications: Applicable systems,
Duplex CPU, Dual I/O Expansion System only;
Number of Power Supply Units,
2 Units max. (for duplex operation);
Number of I/O Units, 9 Units max.
(Slot number 0 is reserved for an,
I/O Interface Unit).
Current consumption: 5V system, 1 OMRON C500-LK201-EV1 Manual. 21A;
26V system, --.
Standards: UC1, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables
C500-LK201-EV1 CV500-FH SYSMAC BUS PC Unit Floppy/Hard Disk Drive For 100 VAC CV500-FHD01-EUM: 31.2K words.
DM: 6K words.
EM: 6Kx3 banks(18K) words.
Instruction processing time (basic instructions): 0.1 µ.s min.
No. of I/O points: 880 points.
Max. no.of con-necting Expansion I/O Racks: 2 Racks OMRON C500-LK201-EV1 Manual.
Max. no. of connecting High-density I/O Units(i.e., Group-2): Unavailable.
Max. no. of con-necting Special I/O Units: 10.
RS-232C: NO.Unit type: CS1 CPU Bus Unit.
Product name:SPU Unit,
(High-speed Data Storage Unit).
Specifications: PC Card slot,
1 PC Card Type II slot Insert an,
OMRON HMC-EF@@@ to use the Memory Card;
Ethernet (LAN) port, 1 port(10/100BASE-TX) OMRON C500-LK201-EV1 Manual.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.56A; 26V, --.
Standards: UC1, CE.
High-speed Collection of System Data.
The CPU Unit can collect large amounts,
of process data, operation data,
inspection data, and other controlled system,
data quickly and automatically save the data,
in external storage media as CSV files. C500-OD I/O Unit Transistor Output 64 pts C500-OD211(3G2A5-OD211).
DC24V 0.1A.Product name: N@@S1- type CPU Units with 30 I/O Points.
Specifications: Power Supply, DC24V; Inputs, 18; Outputs, 12;
Output type: Transistor (sinking).
Program capacity: 8K steps.
memory Data capacity: 8K words.
External powersupply(24 VDC): --.
Current consumption: 5 V, 0.27A; 24 V,0.02A.
Standards: CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection. Unit type: CJ1 Basic I/O Units.
Product name: DC Input/Transistor Output Units.
Specifications: Output type, Sinking;
I/O points, 32 inputs, 32 outputs;
Input voltage,Input current, 24VDC, 4.1mA,
12 to 24VDC, 0.3A;
Commons, 16 points, 1 common;
External connection, MIL connector C500-LK201-EV1 SETUP MANUAL.
No. of words allocated: 4 words.
Current consumption: 5V, 0.14A; 24V, --.
Standards: UC1, N, CE.
A Wide Range of Basic Mixed,
I/O Units for Different Applications,,
and Wiring Methods C500-LK201-EV1 SETUP MANUAL.
One Mixed I/O Unit has connectors for,
both inputs and outputs.
Use Mixed I/O Units to easily ,
build space-saving systems.