Unit type: CS1 Special I/O Units.
Name: High speed Counter Units.
Specifications: Countable channels,
2; Encoder A and B inputs,
pulse input Z signals, Open collector,
Input voltage: 5VDC,12VDC, or 24VDC,
(up to 2 axes for 5 V or 12 V input),
RS-422 line driver;
Max. counting rate, 50kHz, 500kHz OMRON CP1H-X40DT1-D HOST CONNECTION MANUAL.
No. of unit numbers allocated: 4.
Current consumption: 5V, 0
CP1H-X40DT1-D45A; 26V, --.
Standards: UC, N, L, CE.
High-Speed, Flexible Control With A,
Wide Array of Features.
Equipped with 2 or 4 Counters and counts,
over a maximum binary range of 32-bits.
Accepting input pulse frequencies of up,
to 500 kHz allows precise control of fast motions.
The Unit is equipped with 4 Digital Inputs,
4 Digital Outputs and 28 Soft Outputs OMRON CP1H-X40DT1-D HOST CONNECTION MANUAL.
A maximum response time of 0.5 ms guarantees,
high-speed closed loop control of applications. Product name: N@@S1- type CPU Units with 30 I/O Points.
Specifications: Power Supply, DC24V; Inputs, 18; Outputs, 12;
Output type: Transistor (sinking).
Program capacity: 8K steps.
memory Data capacity: 8K words.
External powersupply(24 VDC): --.
Current consumption: 5 V, 0 OMRON CP1H-X40DT1-D HOST CONNECTION MANUAL. 27A; 24 V,0.02A.
Standards: CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection. Model: C200H-OD212.
No. of points: 16 pts.
Specifications: 0.3 A, 24 VDC.NO. OF I/O SLOTS: 5 SLOTSOutput method: Analog resolution: 1/6000.
Analog Outputs: 4.Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Thermocouple Input Units.
points Input: 8 inputs.
Signal range selection:
Set separately for each input.
I/O type: R, S, K, J, T, L, B.
Conversion speed: 250 ms/8 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.18A; 26V, 0.06A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and spacee compared,
with previous systems CP1H-X40DT1-D Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CP1H-X40DT1-D Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.