Power supply: AC power supply.
Output method: Transistor output sink type.
Inputs points: 24 points.
Outputs points: 16 points.Size: 60mm.
Type: 4 lines.
Lighting voltage: DC24V.
Color: green.
Large tactile buttons and uniform lighting to create a general space.
Backlight brings a uniform, elegant and pleasant lighting OMRON CS1D-CPU65P HOST CONNECTION MANUAL.
Large tactile buttons are easier to touch
CS1D-CPU65P
Drive rod mechanism to keep the direction of the parallel button, even if the pressure on the side of the.
Damping mechanism to ensure high impact resistance.
A slim body with a thickness of 14.6 mm. Model: CPM2C-24EDT1. Units with 24 I/O points
2 Fujitsu connectors.
Inputs: 16 inputs.
Outputs: 8 outputs.
Input type: 24 VDC OMRON CS1D-CPU65P HOST CONNECTION MANUAL.
Output type: sourcing transistor.CPU Unit: CP1L-L CPU Units with 10 Point.
Specifications: CPU type, Memory capacity: 5K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, DC power supply; Output method, Transistor output (sinking);
Inputs, 6; Output, 4.
Standards: UC1, N, L, CE.
High Performing Programmable Controller with Embedded Ethernet OMRON CS1D-CPU65P HOST CONNECTION MANUAL.
"CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port.
"CP1L-M" and "CP1L-L" has a standard-feature peripheral USB port.
Function blocks (FB) allow you to build up modular structure and,
programming of ladder diagrams. Model: C200HW-COM04-V1.
Specifications: Communications port for the Controller Link, SYSMAC LINK Units, one RS-232C port, and a protocol macro function.Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Resistance Thermocouple Input Units.
points Input: 4 inputs.
Signal range selection:
Set separately for each input.
I/O type: Pt100, JPt100.
Conversion speed (resolution):
250 ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.25A; 26V, --.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and spaace compared,
with previous systems CS1D-CPU65P Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CS1D-CPU65P Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.