Product name: CJ2M (Built-inEtherNet/IP) CPU Units.
Specifications: I/O capacity/Mountable Units(Expansion Racks),
2, 560 points/40 Units(3 ExpansionRacks max. );Programcapacity,
20K steps;Data memorycapacity, 64K words,
(DM: 32K words, EM: 32K words ×1 bank);
LD nstruction execution time, 0 OMRON CS1W-SCU21-V1 Manual. 04 μs;
EtherNet/IP function: YES;
Option board slot: YES.
Current consumption (A): 5V, 0
CS1W-SCU21-V17(See note. );24V, --.
Standards: UC1, N, L, CE.
CJ2M for basic machine automation.
The CJ2M Series is ideal for packaging and general.
machine automation needs. Connectivity is assured.
thanks to the built-in USB port and the choice of.
Ethernet and RS-232C/422/485 interfaces on the CPU OMRON CS1W-SCU21-V1 Manual. Name: Bit Slave Units with e-CON Connectors.
Specifications: Inputs; 2 inputs; NPN.
Simple and Intelligent Bit Slaves,
with Industry-standard e-CON connectors.
Slave Units capable of 2-point bit-level distribution.
The I/O power supply is supplied from the communications,
power in the previously connected flat cable, and has a,
short-circuit detection function for protection OMRON CS1W-SCU21-V1 Manual.
Industry-standard e-CON connectors.
Short-circuit protection safeguards the network,
from I/O short circuits.
Simple communications connections,
with flat cable and connectors.
Bit-level distribution to support,
essentially any application. Name: Heat/Cool Temperature Control Module.
Model: C200H-TV103.
Sensor: Platinum resistance thermometer: JPt100, Pt100.
Control output: Current output(transistor output used for cooling outputs).Unit type: CS1 Special I/O Units.
Product name: Isolated-type DC Input Unit.
Input points : 4 inputs.
Signal range: 4 to 20 mA, 0 to 20 mA,
0 to 10 V, ±10 V, 0 to 5 V, ±5 V,
1 to 5 V, 0 to 1.25 V, ±1.25 V.
Conversion speed (resolution):
20 ms/4 inputs, 10 ms/2 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.12A; 26V, 0.12A.
Standards: UC1, N, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,,
with previous systems CS1W-SCU21-V1 OPERATION MANUAL.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CS1W-SCU21-V1 OPERATION MANUAL.
Parameters can be easily displayed and set in an,