Drive rod: ball swing rod type (metal swing rod, resin ball).
Built in switch structure: 1NC/1NO (speed type).
Economical safety limit switch.
The standard gold plated contacts ensure high reliability of the contact.
Can be used for standard load and small load. The type of the drive lever: one way action roller rocker type (horizontal action) OMRON Programmable Terminals Operation Manual.
Conduit size: single catheter type, M20
DRT2-OD08C-1
Built in switch structure: slow motion (1NC/1NO).
Safety limit switch in accordance with global standard EN 50047.
The contact constitutes a complete variety, there is a single point of specification (1NC) and double contact specifications (1NC/1NO, 2NC).
Forced open action structure.
The slow moving contact structure is adopted to ensure that the contact distance is 4mm OMRON Programmable Terminals Operation Manual.
Elevator and escalator can be used. Actuator: Plunger.
Conduit openings: G1/2 (PF1/2).
1NC/1NO (Slow-action).
Robust safety limit switch with metal housing.
Slow-action and snap-action contact with,
certified direct opening operation certification.
Direct opening mechanism (NC contacts only) added to,
enable opening contacts when faults occur, such as fused contacts OMRON Programmable Terminals Operation Manual.
Safety of lever settings ensured using a mechanism that,
engages a gear between the operating position indicator plate and the lever.
Equipped with a mechanism that indicates the applicable,
operating zone, as well as push-button switching to control left and right motion DRT2-OD08C-1 Operation Manual.
Head seal structure strengthened to improve seal properties DRT2-OD08C-1 Operation Manual.
(TÜV: IEC IP67, UL: NEMA 3, 4, 4X, 6P, and 13).
Wide standard operating temperature range: –40 to 80°C (standard type).
Certified standards: UL, CSA, EN (TÜV), and CCC.
Ratings: Standard load; 5 A at 125 VAC.
Cable: VCTF oil-resistant cable *1 DRT2-OD08C-1 Operation Manual.
Actuator: Roller lever.
Cable length : 3 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m avaiilable on standard models DRT2-OD08C-1 Manual.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
connfirmation of operation OMRON Programmable Terminals Operation Manual.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)