Type: plug - in.
Size: 48 x 96mm.
Control output 1: voltage output.
Control output 2: relay output.
Auxiliary output: 2 points.
Communication: -.
Heater disconnection: -.
Event input: -.
Power supply voltage: AC100 ~ 240V.
Using large font PV display (white), improve visibility.
Selection, setting and operation more simple and more group of input / output,
Functional performance is stronger, the function is more perfect and more extensive range of applications E5CC-TQX3ASM-064 Manual
E5CC-TQX3ASM-064
E5EC-800 white LCD-PV display height is about 18mm,
The E5AC-800 white LCD-PV display height is about 25mm improved visibility.
The main body is short, the thickness is only 60mm.
50ms high speed sampling period.
A new type of proportional control allows you to control the valve E5CC-TQX3ASM-064 Manual. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function E5CC-TQX3ASM-064 Manual.
Event input points: -.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance OMRON E5CC-TQX3ASM-064 Communications Manual.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV OMRON E5CC-TQX3ASM-064 Communications Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation OMRON E5CC-TQX3ASM-064 Communications Manual.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. Appearance: L-shaped.
Sensing method: Through beam (with slot).
Sensing distance: 5 mm (slot width).
Output configuration: Light-ON Dark-ON (2 outputs).
Connection method (Cable length): Pre-wired model with standard cable (1 m).
Output type: NPN.
Meeting Customer Needs with.
Ultra-compact Sensors that Mount.
with M3 Screews E5CC-TQX3ASM-064 .
Mount using M3 or M2 screws.
Reliable sensing slot depth of 6.5 mm.
Indication of sensing window for easy confirmation of,
insertion depth.
Bright indicator for confirmation from many directions.
Both light-ON and dark-ON outputs provided E5CC-TQX3ASM-064 Manual.
All models available with either standard cable or,
flexible robot cable.
Load short-circuit protection circuit provided.